A quick-reference, four-chart guide for technicians preparing a GCSE resistance investigation: what to issue, how to connect the meters, what to measure and how to limit heating. For more detailed curriculum practical resources, visit our Curriculum Experiments resources.
Check cold → measure the wire → rebuild for resistor networks → compare resistance

One reusable station for both investigations · check connector compatibility, not only quantities
Both investigations are included. One complete run means all chosen wire lengths or all four resistor arrangements, recorded on one sheet. Repeating both investigations twice needs four records per set, not four sets of equipment.
Allow nine detachable leads per set for the most demanding parallel arrangement with a separate switch and series limiter. Wire is issued as 1.10 m cuts for a maximum 1.00 m test span. Lead, wire-piece and paper spares are rounded up separately across the class. Extra sets receive the same run allocation. Settings and ticks are not saved.
Planning issue: 10 working stations + 1 extra = 11 equipped sets. Both investigations × 2 complete runs = 4 records per set; 44 class records. Provide 22 test resistors and 22 wire-contact clips. Leads: 99 working + 20 spares = 119. Wire: 11 working + 2 spare pieces = 13 cuts of 1.10 m; 14.30 m before cutting waste. Paper: 44 records + 5 spares = 49 sheets. Reuse the equipment and sound wire after cooling/reset.
| Item / issue specification | Per equipped set | Class provision (11 sets) |
|---|---|---|
| 1 | 11 | |
| 1 of each | 11 of each | |
| 1 | 11 | |
| 1 | 11 | |
| 1 complete kit | 11 kits | |
| 1 cut + class spares | 13 cuts (11 + 2 spare) 14.3 m total |
|
| 2 | 22 | |
| 2 | 22 | |
| 1 connection kit | 11 kits | |
| 9 + class spares | 119 leads (99 + 20 spare) |
|
| 1 | 11 | |
| 4 records | 49 sheets (44 + 5 spare) |
Labels, suitable tape/fixings, cutters, any staff check meter or micrometer, and assessed PPE. Add replacement contacts, extra record sheets or different resistor values when required.
The 1.10 m cut and nine-lead allowance describe this layout. The calculator does not select wire diameter, resistance, power ratings, current limits, cooling time or mains-service capacity.
Prepare the wire and resistor pair · trace the measured section · pilot every configuration

Mount uniform wire straight, not stretched. Keep the scale readable. Label R₁, R₂ and the separate limiter; check resistor values, ratings and sound contacts.
Select DC ranges and correct sockets. Check the ammeter input/fuse and lead ratings. Use a high-input-resistance voltmeter; never use an Ω range on a powered circuit.
Check the shortest wire and the parallel pair. Establish readable low-current measurements, brief on-time and cooling/reset. Do not assume one supply setting suits both investigations.
| Test section | Connection / position | Critical check |
|---|---|---|
| Wire length | Two contacts define L; the voltmeter uses those same endpoints. | L is the contact separation. Keep unused wire clear; never test L = 0. |
| R₁ or R₂ alone | Insert one labelled resistor at a time; measure across it. | Retain each identity and measured value for the network comparison. |
| Series pair | R₁ then R₂ in one path; voltmeter spans the pair. | Do not measure voltage across only one resistor and call V/I the pair’s resistance. |
| Parallel pair | Both resistors connect between the same two junctions. | Use total current before the split, not a single branch current. |
| Test / configuration | L (cm) | V (V) | I (A) | R = V/I (Ω) |
|---|---|---|---|---|
| Wire / length ____ | ____ | ____ | ____ | ____ |
| R₁ alone | — | ____ | ____ | ____ |
| R₂ alone | — | ____ | ____ | ____ |
| R₁ + R₂ series | — | ____ | ____ | ____ |
| R₁ and R₂ parallel | — | ____ | ____ | ____ |
Expand the wire record for every length. Record run ID, wire alloy/diameter, contact positions, resistor IDs, meter ranges, supply/limiter settings and any drift. Convert mA to A before using V/I.
Check the circuit and units first · retain raw readings · switch off before changing anything
| Problem | What to check | Technician action |
|---|---|---|
| No current or unexpected zero | Open switch, wrong socket/range, loose contact, blown meter fuse or disconnected test section. | Switch off. Trace the intended path and ask staff to check the meter. Do not bypass a fuse or increase voltage blindly. |
| High current or rapid drift | Short wire, bypassed test resistor, low limiter setting, parallel connection or current limiting. | Switch off immediately. Staff check the cold circuit and ratings; re-pilot before resuming. Do not move contacts live. |
| Resistance changes at one length | Heating, damaged wire, broad/loose contacts, stretching or inconsistent length definition. | Use the approved cooling routine and consistent contact points. Repeat after reset; keep both readings and note the cause. |
| Network result looks wrong | Voltmeter spans only one series resistor, ammeter is in one parallel branch, or a lead bypasses a resistor. | With power off, identify the two network endpoints and trace both branches. Rebuild, check and repeat. |
| R is huge, tiny or undefined | mA entered as A, V/I inverted, wrong units, near-zero current or an unsuitable meter range. | Convert units and inspect the original paired readings. Do not divide by zero; a zero reading does not mean zero resistance. |
| Repeats disagree or R–L misses zero | Contact/lead contributions, changing temperature, wire non-uniformity or measurement resolution. | Compare the spread and repeat reference checks. Keep a justified best fit; do not erase a non-zero intercept or force agreement. |
Reference check: 15 October 2026. AQA scope and circuit principles [1] [2] [3]; IOP measurement and wire investigations [4] [5] [6]; HSE general electrical and assessment guidance [7] [8]. Full sources and the source/adaptation distinction appear below the printable area.
The example length range, nine-lead issue and calculator are editorial choices requiring local approval and a pilot. No external organisation has approved this guide.
Explore buying guides, practical resources and laboratory reference information.
This Technician Practical Essentials guide brings together apparatus issue, wire preparation, circuit checks, V–I measurements and safe reset for two resistance investigations. It complements our Curriculum Experiments resources.
Source basis and adaptation: P02 supplies the established page layout, calculator behaviour and four-chart print approach. AQA defines the practical coverage; IOP provides related measurement and wire-investigation guidance. [1] [2] [4] [5] [6] The use of a separately labelled series limiter, two test resistors, a 20–100 cm example span, 1.10 m wire cuts, nine leads and one record per investigation run is an editorial preparation design. It is not a verbatim source procedure or a validated equipment package.
A — wire length: change only the measured active length while keeping the wire material, diameter and temperature as consistent as practicable. B — combinations: measure R₁ and R₂ separately, then the same pair in series and in parallel. Both parts belong to the mapped resistance activity. Changing voltage to map the behaviour of a lamp, diode and resistor belongs to the separate I–V practical, P04. [1] [2]
P17 (series and parallel circuits) and P18 (wire resistance) are related supporting topics in the programme. This P03 base issue deliberately brings the wire-length and resistor-combination work together; it does not need a separate station for every configuration.
Measure the separation of the actual electrical contacts, not the total cut length, the ruler’s end or the distance between clip handles. Keep one contact fixed and move the other only with power off. Leave any unused tail unconnected and away from other terminals.
For a series pair, the voltmeter spans both resistors. For a parallel pair, it spans the two common junctions and the ammeter measures the incoming total current. The separate limiter remains outside this measured section.
Measurement approximation: the usual two-meter circuit assumes voltmeter current is negligible compared with test current. Select a sufficiently high-input-resistance voltmeter and appropriate test values; analogue meter loading or appreciable contact resistance may need a revised method. A staff resistance-meter check is useful on disconnected components, but does not replace the student V–I measurements. [6]
The example span starts at 100 cm and steps down to 20 cm, but the shortest usable length depends on the actual alloy, diameter, supply and limiter. IOP warns that low-resistance wire can demand excessive current and that supply behaviour can affect observations. [4] Check the whole range before issue, rather than copying a nominal voltage from another wire specification.
Use the lowest approved current that gives useful meter resolution, switch on only long enough for a stable paired reading, and allow the pilot-established cooling time. Recheck a reference length at the end. A stable display is helpful but does not prove that the wire has stayed at its initial temperature. Do not use touch to assess temperature. [5]
The limiter helps restrict current; it is not R₁ or R₂. A rheostat may be used at a staff-approved setting, with correct two-terminal connections and a verified non-zero limiting resistance. Its own current and power ratings must be adequate.
The shortest wire and the lowest-resistance network can impose different demands. Staff may need different approved settings for A and B. Record changes and measured V and I; the supply dial alone is not the test voltage.
Staff should check component dissipation as well as total current: P = VI for a component using the voltage across it and current through it. In a parallel pair, each resistor experiences the network voltage, while the supply carries the combined current. A resistor’s rated power is an upper specification under stated conditions, not a target operating level. [3] The calculator does not perform this electrical design check.
R = V / IUse V in volts, I in amperes and R in ohms (Ω). Convert milliamp readings first: 100 mA = 0.100 A. Calculate R from each valid pair before finding a mean for the same length or configuration. [6]
Arithmetic illustration only — not a setting or observed result: a measured 0.60 V and 0.120 A give R = 5.0 Ω. Two hypothetical resistors measured as 10.0 Ω each would ideally give 20.0 Ω in series and 5.0 Ω in parallel. Actual results depend on the real components, contacts, temperature and instruments.
Optional technician calculation: for two ideal resistors, Rparallel = (R₁ × R₂)/(R₁ + R₂), derived from their equal voltage and additive currents. AQA does not require students to calculate total resistance from the individual values of parallel resistors; measuring the network using V/I still belongs to the practical. [3] Keep this distinction clear when preparing student materials.
Fit the wire data according to the observed pattern, retain anomalous points with notes and consider a non-zero intercept rather than suppressing it. A rising R–L trend is evidence about this wire under these conditions; it does not by itself determine resistivity without a cross-sectional-area measurement. [4] Additional measurements at one unchanged setting are not a full repeat of an investigation.
| Configuration | Detachable leads |
|---|---|
| Wire or one test resistor | 5 around the loop (supply, switch, ammeter, limiter, test section) + 2 voltmeter leads = 7. |
| Two test resistors in series | Add the link between R₁ and R₂: 6 loop leads + 2 voltmeter leads = 8. |
| Two test resistors in parallel | Use two leads for the extra resistor branch: 5 main-loop leads + 2 branch links + 2 voltmeter leads = 9. |
The class calculator stocks the maximum nine-lead arrangement per set, then adds spare leads. Two wire-contact adapters and compatible junction/stackable-connector provision are counted separately. Integrated boards, captive leads, extra safety components or non-stackable terminals can change the real requirement; trace the assembled kit before issue.
The fixed example below uses 10 working stations + 1 extra set; two complete runs of each investigation; 20% spare leads, 10% spare wire pieces and 10% spare paper. Changing the live calculator updates Chart 2, not this explanatory example.
10 + 1 = 11 equipped sets.
2 test resistors × 11 = 22 resistors.
9 leads × 11 = 99 working leads.
20% × 99 = 19.8, rounded up to 20 spares.
99 + 20 = 119 leads.
11 working pieces + ceiling(10% × 11) = 13 pieces.
13 × 1.10 m = 14.30 m of wire before cutting waste.
Sound wire is reused across all selected runs. Spare pieces do not create additional stations.
2 investigations × 2 runs × 11 sets = 44 full records.
10% × 44 = 4.4, rounded up to 5 spare sheets.
44 + 5 = 49 sheets.
Each wire sheet contains every chosen length; each network sheet contains all four configurations.
Plan shared preparation tools, assessed PPE, supply capacity, cooling time, pilots beyond the extra-set allocation and extra components separately. For a one-part lesson or another wire-cut length, revise the issue calculation rather than using these fixed assumptions unchanged.
Use the school’s approved practical method, current authorised school-science safety guidance and the instructions for the actual supply, meters, rheostat and resistors. HSE provides a general framework for equipment checks and risk assessment; it does not approve this school station. [7] [8] Inspect sharp wire ends and damaged insulation, keep the bench dry, and agree fault reporting, isolation and safe handling before issue.
No member-only CLEAPSS procedure or product-specific instructions were reviewed for this draft. The published sources do not establish that this adaptation has been trialled. Trained staff must approve the method and risk assessment and pilot all configurations before publication and classroom use.
Public sources checked 15 October 2026. Source coverage is distinguished from the editorial station design.
No external source organisation has approved this guide. Technical review and local validation remain separate from the web-source check.
Have feedback or a useful technician tip? Please contact us.
Draft prepared: 15 October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.
Build a compatible resistance station around the actual wire, mounted resistors, low-voltage equipment and accurate V–I measurements. Check ratings, connector styles and the approved method before ordering.
Links open in a new tab or window. These are catalogue searches, not verified product matches or current-stock guarantees. Confirm the wire alloy/diameter, resistor power ratings, meter inputs and connector arrangement. A high-current supply or a low-voltage label alone does not make a wire test safe.