Better Equipped Technician Practical Essentials

Investigating resistance in electrical circuits

Wire length at constant temperature · resistors in series and parallel

A quick-reference, four-chart guide for technicians preparing a GCSE resistance investigation: what to issue, how to connect the meters, what to measure and how to limit heating. For more detailed curriculum practical resources, visit our Curriculum Experiments resources.

GCSE Physics / Combined ScienceResistance · wire and networksP03 · Technician referencev1.0 October 2026

Print all four charts on A4 portrait. Choose Save as PDF or your printer in the print window. Use 100% scale and turn off browser headers and footers.

To print, use your browser’s Print command: Ctrl+P (Windows) or Cmd+P (Mac).

Scope: two linked investigations supporting AQA Physics required practical 3 and Trilogy required practical 15: the effect of wire length while limiting temperature change, and combinations of resistors in series and parallel. [1] [2] P03 is a Better Equipped planning code. This guide’s length range, wire allowance, resistor pair and lead counts are editorial preparation choices, not a prescribed awarding-body recipe. I–V characteristics are covered by P04; P17 and P18 are related supporting topics. Staff must approve the actual kit, electrical limits and method before issue.
Measure the test sectionVoltmeter across the wire or whole network
Trace the currentAmmeter in series; before a parallel split
Limit heatingLow current; brief readings; cool between
Keep length meaningfulBetween contacts, never a zero-length short
Use paired readingsR = V / I; convert mA to A
Better EquippedTechnician Practical EssentialsP03 · GCSE Physics

Investigating resistance in electrical circuits

The practical at a glance

Check cold → measure the wire → rebuild for resistor networks → compare resistance

Investigating resistance in electrical circuits methodology
Two investigationswire length + resistor combinations
R = V / Ivolts ÷ amperes = ohms (Ω)
Power off to changemove clips or rebuild only when off
Worked approach: reuse one low-voltage V–I station for both investigations. Keep the separate current-limiting component outside the voltmeter’s test section. The setting and minimum wire length must be established by a full pilot.
  1. Approve and pilotSelect the wire, test resistors and meter ranges. Check current and component power at the shortest wire length and with the parallel pair. Agree low-current operation, brief reading times and cooling/reset checks. [5] [7]
  2. Connect with output offConnect DC (+) → switch → ammeter → series current limiter → test section → DC (−). Put the voltmeter across the test section only. Staff check the circuit, sockets, polarity and ranges before switch-on.
  3. A · Set the wire lengthUse one straight, uniform wire beside a metre rule. Measure between the two contact positions. Start with the longest approved length; 100, 80, 60, 40 and 20 cm is an example range to pilot. Never bring the contacts together. [4]
  4. Read, switch off, resetFor each length, take a stable voltage/current pair promptly, then switch off. Allow the agreed cooling time before moving the contact. Keep material and diameter unchanged. Record actual V and I, not the supply dial; stop if readings drift.
  5. Repeat and analyse ARepeat the full length sequence after reset, rechecking contacts. Calculate R for each V–I pair, then compare repeats at each length. Plot R vertically against length horizontally; retain all points and do not force the fit through zero.
  6. B · Test the resistor pairWith power off, replace the wire by R₁ alone, R₂ alone, R₁ + R₂ in series, then the pair in parallel. Measure voltage across each whole test network and total current before its split. Check each rebuild; limit heating.
  7. Repeat, compare and clearRepeat the four network tests after reset. Calculate each total resistance from V/I, compare with the individual values and account for variation. Switch off and isolate as instructed; allow components to cool before inspection and storage. [3] [6]
Low voltage does not prevent hot wires or shorts: never put an ammeter across the supply, bypass the limiter or change connections live. Stop for heating, smell, damage or current above the approved limit. Do not test temperature by touch; follow the local handling and PPE assessment.
Better EquippedTechnician Practical EssentialsP03 · GCSE Physics

Apparatus and materials

One reusable station for both investigations · check connector compatibility, not only quantities

 
Interactive calculator not active. Fixed example: 10 stations + 1 extra; two runs of each investigation; 20% spare leads, 10% spare wire pieces and 10% spare paper. Prepare 11 complete sets, 119 leads, 13 wire cuts (14.30 m) and 49 record sheets. Adjust manually when scripting is unavailable.

Planning issue: 10 working stations + 1 extra = 11 equipped sets. Both investigations × 2 complete runs = 4 records per set; 44 class records. Provide 22 test resistors and 22 wire-contact clips. Leads: 99 working + 20 spares = 119. Wire: 11 working + 2 spare pieces = 13 cuts of 1.10 m; 14.30 m before cutting waste. Paper: 44 records + 5 spares = 49 sheets. Reuse the equipment and sound wire after cooling/reset.

Tick prepared items. Quantities assume sequential reuse after cooling and inspection.
Item / issue specification Per equipped set Class provision (11 sets)
1 11
1 of each 11 of each
1 11
1 11
1 complete kit 11 kits
1 cut + class spares 13 cuts
(11 + 2 spare)
14.3 m total
2 22
2 22
1 connection kit 11 kits
9 + class spares 119 leads
(99 + 20 spare)
1 11
4 records 49 sheets
(44 + 5 spare)

Prepare separately

Labels, suitable tape/fixings, cutters, any staff check meter or micrometer, and assessed PPE. Add replacement contacts, extra record sheets or different resistor values when required.

Wire quantity is not a safety setting

The 1.10 m cut and nine-lead allowance describe this layout. The calculator does not select wire diameter, resistance, power ratings, current limits, cooling time or mains-service capacity.

Reuse basis: wire pieces and apparatus are counted once per equipped set. Runs multiply records only. Spare wire is rounded up as whole pieces; total metres exclude cutting waste and unusable spool ends.
Better EquippedTechnician Practical EssentialsP03 · GCSE Physics

Preparation and apparatus set-up

Prepare the wire and resistor pair · trace the measured section · pilot every configuration

Investigating resistance in electrical circuits set up

1 · Prepare and label

Mount uniform wire straight, not stretched. Keep the scale readable. Label R₁, R₂ and the separate limiter; check resistor values, ratings and sound contacts.

2 · Check the meters

Select DC ranges and correct sockets. Check the ammeter input/fuse and lead ratings. Use a high-input-resistance voltmeter; never use an Ω range on a powered circuit.

3 · Pilot the extremes

Check the shortest wire and the parallel pair. Establish readable low-current measurements, brief on-time and cooling/reset. Do not assume one supply setting suits both investigations.

Series path: DC (+) → switch → ammeter → current limiter → test section → DC (−).
Voltmeter: across the test section’s two endpoints only; exclude the limiter, switch and ammeter. For parallel tests the ammeter is before the branch junction.
Define exactly what the V–I pair measures
Test section Connection / position Critical check
Wire length Two contacts define L; the voltmeter uses those same endpoints. L is the contact separation. Keep unused wire clear; never test L = 0.
R₁ or R₂ alone Insert one labelled resistor at a time; measure across it. Retain each identity and measured value for the network comparison.
Series pair R₁ then R₂ in one path; voltmeter spans the pair. Do not measure voltage across only one resistor and call V/I the pair’s resistance.
Parallel pair Both resistors connect between the same two junctions. Use total current before the split, not a single branch current.
Record prompt — use a full sheet for each investigation run
Test / configuration L (cm) V (V) I (A) R = V/I (Ω)
Wire / length ____ ____ ____ ____ ____
R₁ alone — ____ ____ ____
R₂ alone — ____ ____ ____
R₁ + R₂ series — ____ ____ ____
R₁ and R₂ parallel — ____ ____ ____

Expand the wire record for every length. Record run ID, wire alloy/diameter, contact positions, resistor IDs, meter ranges, supply/limiter settings and any drift. Convert mA to A before using V/I.

Temperature control is an experimental check: keep current low and readings brief, allow cooling and recheck a reference length at the end. A change can signal heating or contact drift. “Constantan” does not mean temperature never matters. [5]
Approved supply / current limit: __________Minimum L / limiter setting: __________Reading / cooling routine: __________Pilot / staff check: __________
Better EquippedTechnician Practical EssentialsP03 · GCSE Physics

Troubleshooting and clear-down

Check the circuit and units first · retain raw readings · switch off before changing anything

Problem What to check Technician action
No current or unexpected zero Open switch, wrong socket/range, loose contact, blown meter fuse or disconnected test section. Switch off. Trace the intended path and ask staff to check the meter. Do not bypass a fuse or increase voltage blindly.
High current or rapid drift Short wire, bypassed test resistor, low limiter setting, parallel connection or current limiting. Switch off immediately. Staff check the cold circuit and ratings; re-pilot before resuming. Do not move contacts live.
Resistance changes at one length Heating, damaged wire, broad/loose contacts, stretching or inconsistent length definition. Use the approved cooling routine and consistent contact points. Repeat after reset; keep both readings and note the cause.
Network result looks wrong Voltmeter spans only one series resistor, ammeter is in one parallel branch, or a lead bypasses a resistor. With power off, identify the two network endpoints and trace both branches. Rebuild, check and repeat.
R is huge, tiny or undefined mA entered as A, V/I inverted, wrong units, near-zero current or an unsuitable meter range. Convert units and inspect the original paired readings. Do not divide by zero; a zero reading does not mean zero resistance.
Repeats disagree or R–L misses zero Contact/lead contributions, changing temperature, wire non-uniformity or measurement resolution. Compare the spread and repeat reference checks. Keep a justified best fit; do not erase a non-zero intercept or force agreement.
Expected pattern, not a result to manufacture: for a uniform wire at stable temperature, longer sections have greater resistance. A series pair has resistance approximately R₁ + R₂; a parallel pair is lower than either resistor alone. Judge differences against repeat variation. [3] [4]
Unexpected heating is a reason to stop, not a successful measurement. Switch off if safe, keep clear and alert staff for heat, smoke, smell or damage. Do not touch hot wire, quench components or attempt live repairs.

Clear-down and reset

01 · Switch off and retainOpen the switch, turn the output off and isolate as instructed. Keep labelled raw V–I pairs, lengths, configurations and notes before dismantling.
02 · Cool and inspectStaff confirm safe handling. Check wire, contacts, resistor mounts and leads; segregate faults. Reuse only sound, identified wire without stretching or kinks.
03 · Reset and storeReturn limiter controls to the approved starting position. Restore multimeter leads to the department’s storage arrangement. Count kit, secure sharp wire ends and leave the supply off.
Prepared by: __________Method / assessment: __________Faults / reset checked: __________

Reference check: 15 October 2026. AQA scope and circuit principles [1] [2] [3]; IOP measurement and wire investigations [4] [5] [6]; HSE general electrical and assessment guidance [7] [8]. Full sources and the source/adaptation distinction appear below the printable area.

The example length range, nine-lead issue and calculator are editorial choices requiring local approval and a pilot. No external organisation has approved this guide.

More practical support from Better Equipped

Explore buying guides, practical resources and laboratory reference information.

Visit Better Resources →

About this guide

This Technician Practical Essentials guide brings together apparatus issue, wire preparation, circuit checks, V–I measurements and safe reset for two resistance investigations. It complements our Curriculum Experiments resources.

Source basis and adaptation: P02 supplies the established page layout, calculator behaviour and four-chart print approach. AQA defines the practical coverage; IOP provides related measurement and wire-investigation guidance. [1] [2] [4] [5] [6] The use of a separately labelled series limiter, two test resistors, a 20–100 cm example span, 1.10 m wire cuts, nine leads and one record per investigation run is an editorial preparation design. It is not a verbatim source procedure or a validated equipment package.

Two investigations, not an I–V sweep

A — wire length: change only the measured active length while keeping the wire material, diameter and temperature as consistent as practicable. B — combinations: measure R₁ and R₂ separately, then the same pair in series and in parallel. Both parts belong to the mapped resistance activity. Changing voltage to map the behaviour of a lamp, diode and resistor belongs to the separate I–V practical, P04. [1] [2]

P17 (series and parallel circuits) and P18 (wire resistance) are related supporting topics in the programme. This P03 base issue deliberately brings the wire-length and resistor-combination work together; it does not need a separate station for every configuration.

Define the test section before measuring

Wire contacts and the ruler

Measure the separation of the actual electrical contacts, not the total cut length, the ruler’s end or the distance between clip handles. Keep one contact fixed and move the other only with power off. Leave any unused tail unconnected and away from other terminals.

The resistor network has two endpoints

For a series pair, the voltmeter spans both resistors. For a parallel pair, it spans the two common junctions and the ammeter measures the incoming total current. The separate limiter remains outside this measured section.

Measurement approximation: the usual two-meter circuit assumes voltmeter current is negligible compared with test current. Select a sufficiently high-input-resistance voltmeter and appropriate test values; analogue meter loading or appreciable contact resistance may need a revised method. A staff resistance-meter check is useful on disconnected components, but does not replace the student V–I measurements. [6]

Keeping heating small

The example span starts at 100 cm and steps down to 20 cm, but the shortest usable length depends on the actual alloy, diameter, supply and limiter. IOP warns that low-resistance wire can demand excessive current and that supply behaviour can affect observations. [4] Check the whole range before issue, rather than copying a nominal voltage from another wire specification.

Use the lowest approved current that gives useful meter resolution, switch on only long enough for a stable paired reading, and allow the pilot-established cooling time. Recheck a reference length at the end. A stable display is helpful but does not prove that the wire has stayed at its initial temperature. Do not use touch to assess temperature. [5]

The limiter is not part of the result

The limiter helps restrict current; it is not R₁ or R₂. A rheostat may be used at a staff-approved setting, with correct two-terminal connections and a verified non-zero limiting resistance. Its own current and power ratings must be adequate.

Approve both investigations separately

The shortest wire and the lowest-resistance network can impose different demands. Staff may need different approved settings for A and B. Record changes and measured V and I; the supply dial alone is not the test voltage.

Staff should check component dissipation as well as total current: P = VI for a component using the voltage across it and current through it. In a parallel pair, each resistor experiences the network voltage, while the supply carries the combined current. A resistor’s rated power is an upper specification under stated conditions, not a target operating level. [3] The calculator does not perform this electrical design check.

Calculations and interpretation

From a paired reading

R = V / IUse V in volts, I in amperes and R in ohms (Ω). Convert milliamp readings first: 100 mA = 0.100 A. Calculate R from each valid pair before finding a mean for the same length or configuration. [6]

Wire graph and network comparison

Plot wire resistance against measured length, with units. Do not treat this as an I–V graph. For the networks, compare separately measured values and repeat spread; a series pair should add, while a parallel pair gives a lower equivalent resistance. [3] [4]

Arithmetic illustration only — not a setting or observed result: a measured 0.60 V and 0.120 A give R = 5.0 Ω. Two hypothetical resistors measured as 10.0 Ω each would ideally give 20.0 Ω in series and 5.0 Ω in parallel. Actual results depend on the real components, contacts, temperature and instruments.

Optional technician calculation: for two ideal resistors, Rparallel = (R₁ × R₂)/(R₁ + R₂), derived from their equal voltage and additive currents. AQA does not require students to calculate total resistance from the individual values of parallel resistors; measuring the network using V/I still belongs to the practical. [3] Keep this distinction clear when preparing student materials.

Fit the wire data according to the observed pattern, retain anomalous points with notes and consider a non-zero intercept rather than suppressing it. A rising R–L trend is evidence about this wire under these conditions; it does not by itself determine resistivity without a cross-sectional-area measurement. [4] Additional measurements at one unchanged setting are not a full repeat of an investigation.

Why the lead allowance is nine

Connection count for this exact arrangement
Configuration Detachable leads
Wire or one test resistor 5 around the loop (supply, switch, ammeter, limiter, test section) + 2 voltmeter leads = 7.
Two test resistors in series Add the link between R₁ and R₂: 6 loop leads + 2 voltmeter leads = 8.
Two test resistors in parallel Use two leads for the extra resistor branch: 5 main-loop leads + 2 branch links + 2 voltmeter leads = 9.

The class calculator stocks the maximum nine-lead arrangement per set, then adds spare leads. Two wire-contact adapters and compatible junction/stackable-connector provision are counted separately. Integrated boards, captive leads, extra safety components or non-stackable terminals can change the real requirement; trace the assembled kit before issue.

Worked preparation example

The fixed example below uses 10 working stations + 1 extra set; two complete runs of each investigation; 20% spare leads, 10% spare wire pieces and 10% spare paper. Changing the live calculator updates Chart 2, not this explanatory example.

Reusable apparatus and leads

10 + 1 = 11 equipped sets.
2 test resistors × 11 = 22 resistors.
9 leads × 11 = 99 working leads.
20% × 99 = 19.8, rounded up to 20 spares.
99 + 20 = 119 leads.

Wire cuts and total length

11 working pieces + ceiling(10% × 11) = 13 pieces.
13 × 1.10 m = 14.30 m of wire before cutting waste.
Sound wire is reused across all selected runs. Spare pieces do not create additional stations.

Runs and records

2 investigations × 2 runs × 11 sets = 44 full records.
10% × 44 = 4.4, rounded up to 5 spare sheets.
44 + 5 = 49 sheets.
Each wire sheet contains every chosen length; each network sheet contains all four configurations.

Outside the calculator

Plan shared preparation tools, assessed PPE, supply capacity, cooling time, pilots beyond the extra-set allocation and extra components separately. For a one-part lesson or another wire-cut length, revise the issue calculation rather than using these fixed assumptions unchanged.

Local approval and review

Use the school’s approved practical method, current authorised school-science safety guidance and the instructions for the actual supply, meters, rheostat and resistors. HSE provides a general framework for equipment checks and risk assessment; it does not approve this school station. [7] [8] Inspect sharp wire ends and damaged insulation, keep the bench dry, and agree fault reporting, isolation and safe handling before issue.

No member-only CLEAPSS procedure or product-specific instructions were reviewed for this draft. The published sources do not establish that this adaptation has been trialled. Trained staff must approve the method and risk assessment and pilot all configurations before publication and classroom use.

Have feedback or a useful technician tip? Please contact us.

Draft prepared: 15 October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.