We use cookies to give you the best experience possible. By continuing to use the site, you indicate that you accept cookies. See our cookies policy here.
Better Equipped Technician Practical Essentials
A quick-reference, four-chart guide for technicians: what to issue, how to control the two comparisons, which measurements to record and how to cool and reset safely. For more detailed practical resources, visit our Curriculum Experiments resources.
Scope: surface effects in infrared emission and absorption, supporting AQA Physics required practical 10 and Trilogy required practical 21. [1] [2] AQA specifies absorption or radiation; this guide offers two distinct routes. A is a warm water-filled Leslie’s cube with a relative-radiation detector. B is a matched black/shiny metal-can comparison using contact temperature probes.
P10 is a Better Equipped planning code. Station design, the paired-can method, stock allowances and example timing are editorial choices, not an awarding-body recipe. This is not P02’s insulation comparison, a cooling-only emission test, an absolute emissivity measurement or a thermal-camera temperature survey. Local technical review and a full pilot remain necessary.
Identify the surface → keep the comparison fair → record the correct quantity → cool and reset

Separate A/B station counts · reusable apparatus · explicit cube-fill and paired-can water budgets
A complete A series is one full face scan with temperature and reference rechecks. A complete B series is one paired heating record. The series count applies to every station; include enough series for shared-group rotations and repeats. Include demonstration/extra complete stations in the A/B counts.
Cube fills are budgeted independently of scans: a single fill may support several scans only while temperature remains within the approved band. B uses fresh water in both cans for each full series. The 1,500 mL cube and 100 mL can defaults are editable stock examples, not instructions to use those fills. Check the actual working fill, capacity and headspace. Reserve water rounds up to whole mL; paper spares round up to whole sheets. Settings and ticks are not saved.
Planning issue: 2 emission stations (A) + 10 absorption stations (B). Provide 2 cube/detector sets, 20 cans and 22 contact temperature probes. Two complete series per station = 4 A records + 20 B records; 24 records + 3 spare sheets = 27 sheets. Cube water: 3,000 mL for one full fill per cube. Absorption water: 4,000 mL. Combined water: 7,000 mL + 700 mL reserve = 7,700 mL. Counts do not set safe temperatures, distances or fills; heating, washing and additional refills are planned separately.
| Item / issue specification | Per route station | Class provision (A: 2; B: 10) |
|---|---|---|
| 1 complete kit / A | 2 kits | |
| 1 complete kit / A | 2 kits | |
| 1 / A | 2 kits | |
| 1 / A | 2 kits | |
| 1 matched pair / B | 10 pairs (20 cans) |
|
| 1 two-probe kit / B | 10 kits | |
| 1 complete kit / B | 10 kits | |
| 1 / B | 10 kits | |
| 1 / B | 10 kits | |
| A: 1 × 1,500 mL / session B: 2 × 100 mL / series |
7,700 mL (A 3,000 + B 4,000 + 700 reserve) |
|
| 2 / station | 27 sheets (24 + 3 spare) |
|
| Plan separately | Shared / person-based provision |
Match geometry and temperature → distinguish signal from temperature → retain both raw records

Label finishes without covering test faces. Match can construction and lids. Check leaks, coatings, guards, mounts and connections.
A: check detector mode, units, reference and field of view. B: compare probes in the same mixed water; fix equal immersion depths. Record resolution.
Pilot both routes. Agree temperature bands, detector distance, source geometry, exposure and cooling. Plan shared-station access.
| Check | A · Emission | B · Absorption |
|---|---|---|
| Temperature | Allow cube equilibration; record water temperature with each face reading. Repeat a scan that drifts outside the agreed band. | Equal measured portions and comparable stable starts; retain both initial temperatures. Do not top up to force agreement. |
| Geometry | Same face-to-detector distance, height and perpendicular view; observed area entirely inside each face. | Equal source-to-facing-surface distance and exposure; same lids, bases and probe depths. Neither can shadows the other. |
| Measurement | Same detector, range and dwell; approved shutter between readings. Recheck first face for drift. | Simultaneous contact temperatures; same timing and source routine. Swap can positions only between complete reset runs. |
| Face / time | Cube water T (°C) | Detector S / unit* | Geometry / drift note |
|---|---|---|---|
| Matt black / ____ | ____ | ____ | ____ |
| Shiny metal / ____ | ____ | ____ | ____ |
| First-face recheck | ____ | ____ | ____ |
| Elapsed t (s) | Black can T (°C) | Shiny can T (°C) | Source / position / note |
|---|---|---|---|
| 0 / before exposure | ____ | ____ | Matched stable starts |
| During / ____ | ____ | ____ | ____ |
| End / ____ | ____ | ____ | Stop reason: ____ |
*Keep the actual detector unit (for example mV), range and zero/reference record. A: add all face IDs and ambient temperature. B: ΔT = Tend − Tstart for each can; record water volume, probe IDs, lamp setting and left/right position.
Check temperature, geometry and sensor mode first · retain results · cool before handling
| Problem | What to check | Technician action |
|---|---|---|
| A · Signal is weak or unstable | Wrong sensor/mode, blocked shutter, warm detector, poor alignment or a face smaller than the field of view. | Stop and check the instrument and cold layout. Use approved shielding/settling; do not bring the detector dangerously close. |
| A · Later faces read lower | Cooling cube, drift, changed distance, warm objects reflected in the shiny face or an altered view. | Check temperatures and first-face recheck. Repeat at comparable temperature in reverse order; keep the cube stationary. |
| B · Can temperatures start differently | Warm retained water/cans, unmatched portions or probes still settling. | Cool and reset with fresh equal portions. Keep original readings; a temperature-rise calculation alone does not remove unequal starting conditions. |
| B · Little difference or swapped ranking | Unequal illumination, different can construction, wet finish, probe touching metal or large heat losses. | Check matched geometry and probes. Swap positions after reset; compare early heating and repeat spread, not only the final temperature. |
| Finish and expected ranking disagree | White paint assumed to be a poor infrared emitter; different coatings or wavelengths; reference temperature not matched. | Record the actual finish and evidence. Do not infer infrared behaviour from visible colour alone or alter readings to fit a ranking. |
| Leak, excessive heat, glare or damage | Unstable source, damaged cable/guard, spilled water, failed coating or poor clearance. | Switch off if safe, keep clear and alert staff. Do not handle wet live equipment, touch-test heat or continue with damaged kit. |
Public references checked: 19 October 2026. AQA scope and concepts [1] [2] [3]; manufacturer detector and emissivity guidance [4] [5] [6]; general HSE safety [7] [8]. Full references and adaptation notes are below the printable area.
The water-filled cube, paired-can design and preparation counts are editorial choices requiring local technical review and a physical pilot. No external organisation has approved this guide.
Explore buying guides, practical resources and laboratory reference information.
This Technician Practical Essentials guide brings together apparatus issue, controlled surface comparisons, temperature and radiation measurements, and safe cooling. It complements our Curriculum Experiments resources.
Source basis and adaptation: P09 supplies the page structure, scoped styling and calculator/print approach. P10’s practical content is newly written. The AQA specification establishes the absorption-or-emission scope. [1] [2] Manufacturer resources clarify relative-radiation detection and infrared-temperature limitations. [4] [5] [6] The water-filled cube, black/shiny water-can comparison, shared-station counts and example timing are this guide’s proposed preparation design, not a verbatim source method or a validated equipment specification.
Use a compatible water-filled Leslie’s cube with identified faces, including matt black and polished metal. Let the warmed cube equilibrate and compare each face with the same relative-radiation detector. Additional faces may be recorded, but their actual coating must be identified. The cited PASCO manual uses an electrically heated cube, not this water-filled arrangement. [5]
Use two matching metal cans that differ in outer finish, with equal water portions and supported immersion probes. A common approved radiant source exposes both under matched conditions. Record the temperature rises from comparable starts. This is an editorial, pilot-dependent classroom comparison; no consulted source establishes its performance with your equipment.
AQA’s wording allows absorption or radiation. This page provides both for departments choosing the broader investigation; it does not add an awarding-body requirement. [1] [2] The calculator budgets both routes with independent station counts. A single-route lesson needs a revised issue rather than treating the unused route’s quantities as essential. Shared stations need enough pupil measurement access and time.
A suitable thermopile detector provides a response to incident thermal radiation. With a compatible readout it can be used to compare surfaces, but a voltage signal is not automatically watts, watts per square metre or an absolute emissivity. Keep the actual instrument’s units and operating range. [4] The selected model’s calibration, spectral response, viewing geometry and thermal stability must be checked before issue.
For a temperature-only infrared thermometer, the displayed temperature is calculated using an emissivity assumption. Shiny metal can therefore give a misleading apparent temperature. [6] P10 uses a radiation-signal detector for A and contact probes for actual water temperatures. Do not put identical tape patches over the compared faces: that changes the surface being tested. A thermal camera or temperature-only IR instrument needs a separately designed interpretation and is not a direct substitution.
Mark safe detector positions around the cold cube before filling. Measure distance from each face to the same detector reference, not from the cube centre. Aim normally at a central area wholly inside the face. Keep the sensor at the same height and avoid viewing the rim, neighbouring faces or hot water directly. These positioning details are editorial controls to pilot.
A shared water bath is a practical way to bring cube walls towards comparable temperatures, not proof that every surface is exactly isothermal. Allow settling, record water temperature with each reading and define an acceptable drift band. Recheck the first face and reverse the scan order on repeats. Do not compare one face while hotter with another after substantial cooling.
Follow the detector’s own zero, shutter and settling instructions. Continuous exposure can warm the detector and shift its response; the PASCO example uses shielding between observations. [5] Store raw readings and the zero/reference record. Where the approved method subtracts a reference, retain both values and subtract it only once; do not add an extra correction to a display already zeroed that way. Keep people, hot lamps and changing surroundings out of reflective sightlines.
Use the same underlying metal, can geometry, wall thickness, exposed area, matching lids and comparable thermal capacity. A black plastic beaker versus a shiny metal can changes more than surface finish. Wrapping one can in loose foil can introduce an insulating air gap. Use a properly prepared, dry, durable coating or matched purpose-made pair; keep identification labels off the exposed area. These are preparation controls, not a product-compatibility claim.
For B, the water starts at a comparable temperature close to the room, not at the hot filling temperature used for A. Measure equal portions, check probes together in mixed water and then secure them at matching immersion depths clear of walls and bases. The 100 mL default is a stock-planning example. Establish a consistent mixing/settling routine before the baseline; do not remove lids or stir one can alone during a timed run.
Place both cans in a symmetric field from the same source, with equal source-to-facing-surface distance, angle and exposed area. Equal distance alone does not guarantee equal irradiance if the reflector or beam is uneven. Pilot source coverage and repeat with left/right can positions exchanged after cooling and reset. Keep the source and its output fixed during each run; retain source warm-up/exposure timing so repeats are comparable.
Choose a laboratory source documented as suitable for infrared/thermal-radiation work. Visible brightness is not a measurement of infrared output. An incandescent thermal source can emit visible as well as infrared radiation, so this simple test does not isolate a narrow infrared band or determine spectral absorptivity. Do not substitute an LED lamp based on brightness alone, add improvised optical filters, or make an unreviewed UV/laser setup.
ΔT = Tend − TstartMean rise rate = ΔT / ΔtUse the same elapsed interval and units for both cans. Plot water temperature vertically against elapsed time horizontally, with separate traces. A larger early rise supports stronger net heating only when thermal capacity, starts and exposure are comparable. The rate is in °C/s (or °C/min), not watts.
Compare the same detector’s response by face, with temperatures and reference checks alongside it. A bar chart can show repeated signals and their spread; label the actual detector unit. Do not turn a mV ratio into a percentage emissivity without the necessary calibration and model. A non-zero background or reflected radiation can affect a simple ratio.
A temperature rise reflects energy stored after concurrent losses, not the full energy absorbed from the source. Conduction, convection, evaporation, emission and sensor lag may all matter. Larger final temperatures are therefore not direct measurements of an absorption coefficient. Early-time comparison helps limit some losses but does not eliminate them. These are limitations of the proposed paired-can energy balance, rather than observed results.
AQA distinguishes real emission/absorption from an ideal black body. [3] Do not treat matt black as perfect or polished metal as having zero emission. The PASCO example also shows why visible white paint need not be a poor infrared emitter. [5] Report the observed ranking for the tested finish, source and detector; do not impose a universal colour ranking.
The fixed example uses 2 emission stations, 10 absorption stations, two series per station, one 1,500 mL cube fill, 100 mL per can per run, 10% water reserve and 10% spare paper. Changing the live calculator updates Chart 2, not this explanatory example.
2 A stations = 2 cubes and 2 radiation-detector kits.
10 B stations = 20 cans and 20 immersion probes.
Add 2 cube contact probes = 22 contact probes overall.
A records: 2 × 2 = 4; B records: 10 × 2 = 20.
24 records + ceiling(10% × 24) = 27 sheets.
A: 2 cubes × 1 fill × 1,500 mL = 3,000 mL.
B: 10 pairs × 2 cans × 2 runs × 100 mL = 4,000 mL.
Base water = 7,000 mL.
10% preparation reserve = 700 mL.
Total = 7,700 mL (7.7 L); washing/rinsing water is extra.
The combined water total is a stock budget, not one hot-water batch: A and B need different starting conditions. The cube’s fill number is independent of its scan number because the pilot must establish how many scans remain valid before cooling becomes excessive. Increase planned fills when required; do not top up a hot cube in the middle of a scan. Spare water does not create stations. Drying, cooling, heating capacity, individual pupil sheets and replacement equipment remain separate.
Use trained staff for hot filling and handling; choose the lowest approved temperature/output that gives a readable result. Check vessel vents, stable supports, lamp guards, clearances, spills and the whole class’s electrical load. Never improvise a pressure-tight lid or a heater inside an unsuitable cube. Follow local isolation, first-aid and disposal arrangements. [7] [8]
Public AQA, manufacturer and HSE sources were consulted. No member-only CLEAPSS procedure, instructions for the school’s actual cube/can/source set, or physical pilot results were reviewed. The matched-can implementation is not validated by those sources. Trained staff must check current authorised school-science guidance and actual instructions, complete technical review and pilot the full method before publication and classroom use.
Public sources checked 19 October 2026. Concept and instrument references are distinguished from the proposed station design.
No external source organisation has approved this guide. Historical teaching examples and instrument ratings are not local safety limits.
Have feedback or a useful technician tip? Please contact us.
Draft prepared: 19 October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.
Build separate emission and absorption stations around a compatible cube, radiation detector, source and matched can pair. Check sensing mode, thermal ratings, working fills, mounting and local approval before choosing equipment.
Links open in a new tab or window. These are catalogue searches, not verified product matches or current-stock guarantees. Check that the detector reports a suitable radiation signal, not only apparent temperature. Confirm the matched can pair and suitable source separately; do not assume a generic lamp or can is suitable for this method.