Login

Skip to the practical guide

Better Equipped Technician Practical Essentials

Investigating force and extension

Measuring how a spring stretches under a known load

A quick-reference, four-chart guide for technicians preparing a GCSE spring investigation: what to issue, how to secure the apparatus, how to measure extension and how to check loading, unloading and repeat results. For more detailed curriculum practical resources, visit our Curriculum Experiments resources.

GCSE PhysicsSprings · force · extensionP06 · Technician referencev1.0 October 2026

Print all four charts on A4 portrait. Choose Save as PDF or your printer in the print window. Use 100% scale and turn off browser headers and footers.

To print, use your browser’s Print command: Ctrl+P (Windows) or Cmd+P (Mac).

Scope: one vertical spring investigation supporting AQA Physics required practical 6 and Trilogy required practical 18: the relationship between applied force and spring extension. [1] [2] P06 is a Better Equipped planning code. The no-hanger baseline, five-piece planning issue, separate unloading record and calculator are editorial choices, not an awarding-body recipe. Staff select the actual masses and approve the total load, extension and support arrangement. The core method stays within an approved non-destructive range; rubber bands, spring combinations, oscillations and deliberate permanent stretching are outside the base issue.
Secure the supportClamp the stand; secure the spring
Record the baselineSame lower hook, no hanger
Count the full loadHanger + all attached masses
Measure the changeExtension = reading − baseline
Check the graph axesForce on y; extension on x
Better EquippedTechnician Practical EssentialsP06 · GCSE Physics

Investigating force and extension

The practical at a glance

Secure the stand → record the baseline → load and unload → calculate and compare

Investigating force and extension methodology
One springkeep the same identity through each repeat
e = r − r₀extension, not total spring length
F = mtotalginclude the hanger; use mass in kg
Reference convention: record the lower spring hook with no hanger or added masses as r₀. Keep the top support and ruler fixed. Read that same hook at every load. A hanger-on baseline is a different, incremental method; do not mix the two.
  1. Approve and pilotCheck spring identity, fittings, mass values and stand stability. Trial the proposed loading/unloading range. Agree maximum total suspended mass, extension, clearance and stop conditions before issue. Do not choose limits from the number of masses available. [7]
  2. Secure and alignClamp the stand securely to the bench. Retain the spring on a suitable support and fix the rule vertically beside it without contact. Position a padded catch tray beneath the load; it must not support the hanger during readings. [4]
  3. Record the no-load referenceWith the hanger removed, wait for the spring to settle. Record r₀ at the lower hook, reading horizontally at eye level. Use a scale increasing downwards. The baseline need not be the ruler’s zero; do not move the ruler afterwards.
  4. Load in approved stepsFit the known hanger, then add the selected masses one at a time. At each settled load record the total suspended mass and reading r. Include the hanger and any extra fittings below the spring. Release your supporting hand before taking the reading.
  5. Unload and check returnRemove masses gradually, recording the same load stages as unloading data. Remove the hanger last and record the final no-hanger reading. Stop and report a changed reference, damaged hook or shifting support; do not disguise it by resetting r₀.
  6. Reset and repeatAfter inspection, repeat the complete loading/unloading cycle with the same spring. Record a fresh starting r₀ for the new cycle and retain the previous final check. Unloading points are not independent repeats; keep both branches labelled.
  7. Calculate and compareCalculate e from each cycle’s baseline and F = mtotalg. Plot force F (N) vertically against extension e (m) horizontally. A suitable straight-region gradient gives k in N/m. Keep all data and investigate offsets rather than forcing a fit through zero. [3] [5]
Springs can recoil; masses can fall. Wear the specified eye protection and keep faces and feet clear. Add and remove loads gently; never pull the spring by hand, release a stretched spring suddenly or try to catch falling masses. Stop at the first approved limit or any instability.
Better EquippedTechnician Practical EssentialsP06 · GCSE Physics

Apparatus and materials

One reusable spring station · apparatus counts do not determine a safe load

 
Interactive calculator not active. Fixed example: 10 stations + 1 extra; two complete cycles per set; five slotted mass pieces per set; 20% spare springs and 10% spare paper. Prepare 11 complete sets, 14 springs, 11 hangers, 55 slotted mass pieces and 25 record sheets. Adjust manually when scripting is unavailable.

Planning issue: 10 working stations + 1 extra = 11 equipped sets. Provide 14 springs (11 working + 3 spare), 11 hangers and 55 slotted mass pieces (5 per set). Two complete loading/unloading cycles per set = 22 records; plus 3 spare sheets = 25 sheets. Reuse the same apparatus and spring after checks. Piece counts do not specify mass values or authorise a maximum load.

Tick prepared items. Reuse the same spring for a repeat only after the return and condition checks.
Item / issue specification Per equipped set Class provision (11 sets)
1 11
1 11
1 complete kit 11 kits
1 + class spares 14 springs
(11 + 3 spare)
1 11
1 complete kit 11 kits
1 11
5 pieces 55 pieces
1 kit 11 kits
1 11
2 records 25 sheets
(22 + 3 spare)
Count separately People / shared provision

Prepare separately

Spring/load labels, a written stage-by-stage loading schedule, graphing resources and any locally required screen. Count people for eye protection; do not infer pupil numbers from station numbers.

Issue is not permission to load

Five pieces per set is a stock-planning example, not an instruction to hang all five. Staff approve actual masses, total force, spring travel and stand stability. Spare masses and hangers are not calculated.

Better EquippedTechnician Practical EssentialsP06 · GCSE Physics

Preparation and apparatus set-up

Fix the reference · record the total load · check travel, unloading and return

Investigating force and extension set up

1 · Match and inspect

Identify each spring and hanger. Check hooks, clamps, mass values and the load catcher. Prepare a written mass sequence; check the hanger alone is inside the approved range.

2 · Fix the reading reference

Fix the rule vertically and use the same lower spring hook throughout. Keep the ruler and top attachment still. Read horizontally without bringing the face into the recoil path.

3 · Pilot the complete cycle

Check maximum load and travel, readable steps, settling, gradual unloading and return. Stop before damage. Do not pre-stretch a spring using an unverified mass.

Core baseline: r₀ is the lower-hook reading with no hanger or added load.
At each stage: mtotal includes the hanger and every attached mass; F = mtotalg.
Extension: e = r − r₀. For readings in mm, e (m) = (r − r₀) ÷ 1,000.
Checks before attaching the hanger
Part Required arrangement Avoid
Support and spring Stand secured; top attachment retained; spring vertical. Loose fittings, a tilted stand or an exposed sharp point.
Rule and reference Fixed vertical scale; same lower-hook point; horizontal sighting. Moving the rule, reading the hanger or touching the load.
Hanger and masses Known total mass; approved steps; settled reading after release. Ignoring hanger mass or treating piece count as force.
Travel and catcher Free clearance at the largest approved extension. Load resting on a tray, base or bench during a reading.
Record prompt — expand for every load in each complete cycle
Stage / direction Total mass
m (g)
Force
F (N)
Reading
r (mm)
Extension
e (m)
No hanger / start 0 0 r₀ = ____ 0
Loading / ____ ____ ____ ____ ____
Unloading / ____ ____ ____ ____ ____
No hanger / end 0 0 rend = ____ (rend − r₀)/1,000

Use g = ____ N/kg consistently. Record spring ID, hanger mass, piece values, maximum load, instrument resolution and settling notes. Keep loading and unloading separate; use the original r₀ for that entire cycle.

A hanger-on baseline is not zero total force. An approved preloaded method must pair the additional force ΔF with the additional extension Δe. Do not combine a hanger-on zero with the total-force column above.
Max. total mass / force: __________Max. extension / clearance: __________Mass steps / settling: __________Pilot / support / PPE check: __________
Better EquippedTechnician Practical EssentialsP06 · GCSE Physics

Troubleshooting and clear-down

Check the reference and load first · retain both branches · unload before dismantling

Problem What to check Technician action
Extension is wrong or negative Loaded scale reading used as extension; ruler moved; wrong hook or reversed scale. Check the saved r₀ and the same lower-hook reference. Retain raw readings; restart if the support or rule moved.
Graph has an offset or flat start Hanger omitted, mixed baseline, closed coils/initial tension or unreadably small steps. Check total mass and the reference convention. Staff re-pilot the spring; do not pull coils apart or force a line through zero.
Spring does not return to its start Permanent set, slipped attachment, changed hook position or insufficient settling. Stop, unload safely and label the spring for checking. Preserve the end reading. A replacement needs a new ID and complete record.
Readings scatter or branches differ Oscillation, parallax, contact with the rule/tray, friction or inconsistent settling. Use the same sighting point and settling routine. Keep loading/unloading separate and compare repeated cycles before averaging.
Spring constant is implausible Mass in g rather than kg; extension in mm/cm rather than m; axes reversed; total length used. Recheck F = mg and e = r − r₀. For F on y and e on x, the gradient is k. Do not divide by zero extension.
Stand moves or load loses clearance Loose bench clamp, shifting ruler/support, snagged masses or excessive travel. Stop and keep people clear. Staff make the load safe before adjusting supports. Do not hold a slipping stand while continuing the run.
Proportionality and elastic recovery are different checks. F = ke applies in the proportional region. A curved graph alone does not prove permanent deformation; compare the unloaded return. If no departure appears within the tested range, do not claim to have found either limit. [5] [6]
Mass: g ÷ 1,000 → kgExtension: mm ÷ 1,000 → mGraph: ΔF / Δe → N/m
Make the load safe before changing the apparatus. Never move a loaded stand, remove its clamp under tension or leave suspended masses unattended. Keep clear of falling masses and recoil; use the school’s incident procedure for failed hooks, slipping stands or injury.

Clear-down and reset

01 · Unload graduallyRemove pieces one at a time using the approved handling routine. Remove the hanger last and record the final no-hanger position before moving the rule.
02 · Inspect and identifyCheck spring return, coil/hook damage and every fixing. Keep suspect springs separate; do not straighten, stretch or relabel them as unchanged repeats.
03 · Store unloadedCount masses and hangers back into labelled sets. Keep records with spring IDs. Dismantle only after unloading and store springs without tension.
Prepared by: __________Method / assessment: __________Return / condition check: __________

Public references checked: 15 October 2026. AQA practical scope and equations [1] [2] [3]; related IOP spring work, graph interpretation and elastic terminology [4] [5] [6]; general risk assessment and eye-protection selection [7] [8]. Full sources and adaptation notes are below the printable area.

This non-destructive station, reference convention and issue counts require technical review and a local pilot. No external organisation has approved the guide.

More practical support from Better Equipped

Explore buying guides, practical resources and laboratory reference information.

Visit Better Resources →

About this guide

This Technician Practical Essentials guide brings together apparatus issue, secure spring preparation, consistent force and extension measurements, repeat checks and safe clear-down. It complements our Curriculum Experiments resources.

Source basis and adaptation: P05 supplies the established visual style, calculator behaviour and four-chart print format. P06’s practical content is a new preparation design informed by the public references below. AQA defines the spring investigation; the IOP steel-spring activity supplies a related suspended-spring approach. [1] [2] [4] This guide instead uses a secured attachment, an approved non-destructive range, explicit total-mass records and force-on-y graphing. The issue counts, lower-hook baseline and loading/unloading cycle are editorial choices requiring a local trial, not a verbatim source procedure.

What is being measured?

The investigation changes the applied load and measures the corresponding spring extension. Keep the spring, top attachment, ruler, reading point and settling routine consistent. The independent variable is applied force; extension is the response. Although force is the input, this guide plots force vertically so the straight-region slope has spring-constant units. The alternative axis convention is explained below.

Position reading is not spring length

The core record uses r, a scale position at the same lower spring hook. With the top fixed, the change in that position equals the change in spring length: e = r − r₀ = L − L₀There is no need to align the top of the spring with the rule’s zero. The rule must remain fixed and the same reference point must be visible at every stage.

Total suspended mass is not piece count

Use the hanger’s mass plus every mass and fitting suspended below the spring. With the load settled and freely hanging, its weight gives the applied downward force: F = mtotal × gUse kilograms and the value of g agreed for the lesson. Do not enter a mass in grams directly into a calculation expecting kg. [3]

The spring’s own weight is already present in both readings in this vertical-reference method. The measured extension is the change produced by the added load below it. Do not add the spring’s whole mass to the hanger total as though it were a separate weight at the lower hook.

Choose one baseline convention

Core method: no hanger at the start

Record r₀ with no hanger or additional moving fittings. Read the lower spring hook itself; an attached pointer is not required. When the hanger is fitted, count its weight. This is the convention used in all four printed charts.

Alternative: a documented preload

A department may retain a hanger or pointer as a preload and record rbase. Then pair additional force with additional extension: ΔF = (mtotal − mbase)gΔe = r − rbaseThis is a different record convention. Revise the table and labels before use; do not call a loaded spring “zero total force”.

Initial tension and closed coils: some extension springs show a small-load region that does not follow a simple line through the origin. Check the actual spring in the pilot. Investigate the reference and component behaviour rather than deleting inconvenient data. Do not adopt the historical IOP activity’s coil-opening loads or deliberate permanent-stretching step for an unidentified spring. [4]

Equations, units and graph interpretation

Core calculations

e (m) = [r (mm) − r₀ (mm)] / 1,000F (N) = mtotal (kg) × g (N/kg)F = ke   in the proportional rangeThe spring constant k is expressed in N/m. Record raw positions before calculating extension. Use the actual mass information, not a catalogue picture or an assumed grams-per-piece value. [3]

Read the axes before taking a slope

For F on y and e on x, a suitable straight-region gradient is k = ΔF/Δe. Use a large triangle on the fitted line, not adjacent noisy measurements. If extension is on y and force on x instead, the gradient is 1/k. With centimetres on the extension axis, a force/extension slope is in N/cm; multiply by 100 to obtain N/m. [5]

Draw the fit justified by the data. A straight line through the origin is consistent with proportional behaviour over that range, but do not force an offset or curved trace to fit. Keep loading and unloading as distinct labelled series; examine disagreement before combining them. Compare repeated cycles of the same spring, and state the range used to estimate k. Different springs or a replacement spring require separate identities and analysis.

Arithmetic illustration only — not a loading instruction or observed result: a total suspended mass of 0.100 kg, including its hanger, with g = 9.8 N/kg gives F = 0.980 N. If the measured extension were 0.0200 m within a proportional region, k = F/e would be 49.0 N/m. These invented values demonstrate the units; they do not establish any spring’s safe load or expected answer. A lesson using the approximation g = 10 N/kg should state it and use it consistently.

Proportionality is not the same as elastic recovery

Limit of proportionality

This marks the end of the force–extension relationship being proportional. A curved response requires different interpretation; one constant k does not describe the entire curve. The guide does not require learners to pass this point deliberately. [3] [5]

Elastic limit and the return check

Elastic behaviour means recovery after the load is removed; permanent deformation indicates that the elastic range has been exceeded. A departure from proportionality and a loss of elastic recovery need not occur at the same point. Check the no-hanger return separately. [5] [6]

A final offset can also arise from a slipping support, movement of the ruler, a changed reading point or incomplete settling. Record it before adjusting anything. Staff should inspect the unloaded apparatus and spring. Do not silently redefine zero and present the next measurements as an unchanged continuation. If the approved range produces only proportional, recoverable behaviour, report that tested range rather than inventing a limit.

Technician checks that matter

Support, load path and travel

P06’s station uses a bench-securing clamp and a separate rule-support kit. Select fittings compatible with the real bench, stand and spring. Check retention at the top, hanger security, support rigidity and an unobstructed vertical path. The load must not touch the rule, base or catcher during a reading.

Eye protection and positioning

Provide the eye protection selected by the local assessment for everyone exposed to recoil risk. The related IOP activity requires eye protection and a secured stand; the public CLEAPSS summary explains that the type depends on the risk. [4] [8] Arrange sighting so a learner need not put their face beneath the spring or next to a projecting attachment.

Pilot before deciding the mass issue

Choose a spring and individual mass values that give several readable stages within the approved range. Trial the hanger alone, maximum total load, travel, settling and unloading. Enough supplied pieces for a lesson does not mean that all may be suspended together. Do not increase the load to rescue an unreadable scale.

One cycle is not one data point

A complete cycle includes all approved loading stages, the unloading stages and both no-hanger checks. A new cycle is a repeat only after reset and inspection. One record sheet must have enough space for all points; the short printed table is a prompt, not the full log.

Worked preparation example

The fixed example uses 10 working stations + 1 extra set, two complete cycles per set, five slotted mass pieces per set, 20% spare springs and 10% spare paper. The live calculator updates Chart 2; this explanation remains the fixed example.

Reusable apparatus and spares

10 + 1 = 11 equipped sets.
One working spring per set = 11 springs.
20% × 11 = 2.2 → 3 spare springs.
Spring total = 14.
Provide 11 hangers; 5 × 11 = 55 slotted mass pieces. Their actual mass values must be selected separately.

Complete cycles and records

2 cycles × 11 sets = 22 complete records.
10% × 22 = 2.2 → 3 spare sheets.
Total paper = 25 sheets.
Loading and unloading share each cycle’s sheet. Repeated cycles do not multiply stands, springs, hangers or mass pieces.

Extra sets carry the same cycle allocation and may be used for demonstration or pilot work. Spare springs do not create new stations and do not justify pooling different-spring results. Add further pilots, spare masses/hangers, alternative springs, extra support components, graphing resources and person-based PPE separately. The calculator predicts neither force nor extension and cannot validate a safe working range.

Local approval and review

Trained staff must check the school’s authorised method, the actual equipment instructions, the risk assessment, supervision, mass handling and incident arrangements. HSE supplies a general assessment framework, not approval of this station. [7] A physical pilot, staff sign-off and technical review remain separate from the public-source check.

No member-only CLEAPSS procedure, full GL061 document or manufacturer instructions for the school’s actual kit were reviewed for this draft. The public GL061 summary was read only for the general eye-protection selection principle. The IOP source’s historical safety-check date does not validate this adaptation.

Have feedback or a useful technician tip? Please contact us.

Draft prepared: 15 October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.

Everything you need for this practical

Build a stable spring station around suitable supports, readable length measurement and a known-mass loading system. Check spring characteristics, mass values, hanger compatibility and the locally approved range before ordering.

Spring, load and support — catalogue searches