We use cookies to give you the best experience possible. By continuing to use the site, you indicate that you accept cookies. See our cookies policy here.
Better Equipped Technician Practical Essentials
A quick-reference, four-chart guide for technicians preparing a GCSE density practical: what to issue, how to measure dimensions and displacement, how to subtract container mass and how to check the results. For more detailed curriculum practical resources, visit our Curriculum Experiments resources.
Identify the sample → measure mass and volume → calculate density → reset and repeat

One reusable station for all three methods · two separate cylinders keep the liquid-mass route clear
All three methods are included. One complete run is a new mass/volume determination for one method, recorded on one sheet. Repeats multiply water allowances and records, not solids, balances or cylinders. Extra sets receive the same run allocation.
The base issue has two 100 mL cylinders. Fill controls are preparation estimates, not verified safe settings or measured results: staff must check full immersion, displacement headroom and scale readability. Water assumes a fresh starting fill and a fresh liquid sample for every run; reserve is rounded up to whole mL. Washing/rinsing water is additional. Settings and ticks are not saved.
Planning issue: 10 working stations + 1 extra = 11 equipped sets. Three methods × 2 complete runs = 6 records per set; 66 class records. Provide 11 of each solid and 22 measuring cylinders. Water: 1,100 mL for displacement + 1,100 mL for liquid tests + 220 mL reserve = 2,420 mL (2.42 L). Paper: 66 records + 7 spares = 73 sheets. Reuse apparatus after cleaning/drying; washing water and additional samples are separate.
| Item / issue specification | Per equipped set | Class provision (11 sets) |
|---|---|---|
| 1 | 11 | |
| 1 | 11 | |
| 1 | 11 | |
| 1 | 11 | |
| 1 | 11 | |
| 2 | 22 | |
| 1 | 11 | |
| 1 | 11 | |
| 1 kit | 11 kits | |
| 1 | 11 | |
| D: 50 mL / run L: 50 mL / run |
2,420 mL (2,200 + 220 reserve) |
|
| 6 records | 73 sheets (66 + 7 spare) |
Sample/cylinder labels, tissues and drying space, wash/rinse water, approved collection/disposal arrangements, a room-temperature check and assessed PPE. Add replacement specimens and glassware as needed.
Larger samples may need an approved displacement-can method. A different liquid, shared balance or additional sample needs revised preparation and assessment; it is not covered automatically by this calculator.
Check dry mass · choose a readable volume method · keep the same liquid portion for both measurements

Label the two solids and cylinders D/L before measuring. Check faces, edges, cylinder integrity and free sample fit. Reject floating, absorbent, soluble or water-reactive objects for this base method.
Check balance zero and capacity; check calliper zero and the ruler’s reference mark. Choose graduations that resolve the sample volume. Keep the balance level, stable and away from splashes.
Trial full immersion, trapped-air removal and retrieval. Confirm initial fill and final level both fit the scale. Establish drying time and a fresh empty-cylinder mass for each full liquid run.
| Method | Required mass / volume | Critical check |
|---|---|---|
| A · Regular solid | Dry sample mass; V = L × W × H for a cuboid. | Measure three different dimensions. Convert all lengths before multiplying. |
| B · Irregular solid | Dry sample mass; V = V₂ − V₁ from the same cylinder. | Complete immersion, no bubbles or lost water; account for support displacement. |
| C · Liquid | m = m₁ − m₀; V is the actual liquid volume in cylinder L. | Same cylinder and portion; outside dry. Neither total filled mass nor capacity is the sample value. |
| Method / sample ID | Raw readings — keep the originals | Calculation / result |
|---|---|---|
| A · Cuboid ____ | m = ____ g L = ____ cm; W = ____ cm; H = ____ cm |
V = ____ cm³ ρ = ____ g/cm³ |
| B · Irregular ____ | m (dry) = ____ g V₁ = ____ mL; V₂ = ____ mL |
V₂ − V₁ = ____ cm³ ρ = ____ g/cm³ |
| C · Water ____ | m₀ (empty) = ____ g; m₁ (filled) = ____ g Actual V = ____ mL |
m₁ − m₀ = ____ g ρ = ____ g/cm³ |
Record run ID, instrument resolution, repeat dimensions, sample/cylinder identities and any bubbles, spills or drying issues. For each result, convert to kg/m³ when required. Never use an unreadable or zero displacement as a valid volume.
Check sample identity, zero, units and volume readings · retain raw data · keep equipment dry
| Problem | What to check | Technician action |
|---|---|---|
| Liquid density is too high | Container mass not subtracted; wet exterior; droplets above the meniscus included in the mass. | Check m₀/m₁ and cylinder ID. Repeat with a clean, dry starting cylinder and careful off-balance filling. |
| Irregular-solid density is too low | Final level used as volume; trapped air or support volume making displacement too large. | Use V₂ − V₁. Inspect immersion and bubbles; assess support contribution. Refill and repeat if water was lost. |
| Displacement is tiny or inconsistent | Coarse cylinder graduations, incomplete immersion, absorption, changing water level or a spill. | Select a better-matched sample/cylinder or an approved alternative. Do not force the object down or divide by zero. |
| Cuboid results vary by position | Wrong axis, mixed mm/cm, worn ruler end, calliper zero error or a block that is not truly cuboidal. | Recheck dimensions with gentle contact. Keep repeat values; use a valid geometry or change the volume method. |
| Mass drifts or repeats disagree | Wet sample, retained liquid, changed cylinder, unstable pan, draughts or contact with the bench. | Dry and reset before a full repeat. Check zero and stable readings; do not treat extra display digits as proven accuracy. |
| Glass cracks, sample jams or water spills | Damaged cylinder, dropped dense object, inadequate clearance or an unstable wet-work area. | Stop and alert staff. Do not force out a jammed sample or handle broken glass. Follow local spill and equipment-isolation procedures. |
Public references checked: 15 October 2026. AQA practical scope and density equation [1] [2] [3]; IOP regular-solid and liquid methods [4] [5]; WJEC direct-displacement method [6]; HSE risk-assessment framework [7]. Full sources and adaptation notes are below the printable area.
The two-cylinder design, selected samples, fill estimates and preparation calculator are editorial choices requiring technical review and local pilot checks. No external organisation has approved this guide.
Explore buying guides, practical resources and laboratory reference information.
This Technician Practical Essentials guide brings together apparatus issue, three density-measurement routes, common reading errors and safe clear-down. It complements our Curriculum Experiments resources. The four charts are a preparation reference, not a substitute for the school’s approved method and risk assessment.
Source basis and adaptation: the established P04 layout and calculator behaviour are retained; the density content is newly prepared. AQA supplies the practical scope and equation. [1] [2] [3] IOP and WJEC provide related classroom methods. [4] [5] [6] This guide’s one-cuboid/one-irregular-solid/water issue, two labelled cylinders, paired-mass record, fresh-fill budgeting and repeat counts are editorial preparation choices. The source activities do not validate those choices for a particular school kit.
For a genuine cuboid, volume comes from three perpendicular dimensions. A ruler, callipers or a micrometer may be appropriate depending on size and required resolution. Repeated readings at different positions reveal unevenness as well as reading variation. [4]
Direct cylinder displacement measures the extra occupied volume when the object is fully immersed. An unnoticed air pocket or immersed holder also occupies volume, so it is part of the experimental error unless allowed for. The core method therefore uses a compact, sinking, non-absorbing specimen.
The method pairs one measured liquid volume with the difference between two masses of the same cylinder. Keep its label and any other attachments unchanged. Empty-cylinder mass is not transferable between apparently identical cylinders. [5]
Room-temperature water is the selected preparation example, not a certified density standard. Do not insert a memorised density as a measured result. Other liquids need a revised assessment, suitable cleaning/disposal and separate supply calculations.
ρ = m / V · Vcuboid = L × W × HVirregular = V₂ − V₁ · mliquid = m₁ − m₀Using g and cm³ gives g/cm³. For SI units, use kg and m³. The conversion factor follows from 1 g = 0.001 kg and 1 cm³ = 0.000001 m³: multiply g/cm³ by 1,000 to obtain kg/m³. Convert all three dimensions before multiplying; a millimetre-to-centimetre conversion applies to every length, not just one. [3]
Choose a useful change, not just a large vessel. As a reasoning example, a 1 mL reading uncertainty matters much more to a 2 mL rise than to a 20 mL rise. A narrower cylinder may improve readability but must still admit the sample freely. Both volume readings contribute to the uncertainty in their difference. A more finely graduated instrument helps only when the sample, fit and reading technique also suit it.
Independent runs need a reset. Re-reading an unchanged balance display is not a new full density determination. For the printed plan, repeat dry mass and dimensions for the cuboid; dry and reweigh the irregular solid before a fresh displacement determination; and establish a new clean, dry empty-cylinder mass before refilling for the liquid route. Drying time is part of the preparation, not something the calculator predicts.
Retain each run’s paired data and calculate its density before comparing the spread. Average only comparable results for the same specimen or material under the same method. A shared bias such as a zero error or wrong container mass will not disappear merely because more repeats are taken. Record any exclusions and their reason rather than forcing a target result.
For a specimen too large for the cylinder, an approved overflow-can route may be more suitable. Establish the starting level at the spout, let excess water finish draining, then collect the new overflow caused by full immersion in a suitable empty measuring vessel. Its water demand and extra apparatus are not included in the calculator.
Do not hold down a floating sample with an unaccounted finger or sinker. A sinker correction, absorption control or a coating changes what is measured and needs its own approved method. Density from an object’s external dimensions may be an average including voids, rather than the density of its constituent material.
Liquid graph extension: a department may instead measure several water volumes in the same cylinder, derive the liquid mass at each point and plot mass vertically against volume horizontally. The gradient has density units. IOP describes this approach; it is an extension rather than the independent fixed-portion repeats budgeted here. [5] The source suggests a line through the origin; this guide’s core method uses paired calculations instead. A department using a graph should state its fitting convention and investigate any offset.
The fixed example uses 10 stations + 1 extra set, two runs of each method, two 50 mL working portions per run, 10% water reserve and 10% spare paper. Changing Chart 2’s calculator updates the live issue, not this explanation.
10 + 1 = 11 equipped sets.
Two cylinders per set = 22 cylinders.
One of each solid per set = 11 cuboids + 11 irregular solids.
3 methods × 2 runs × 11 = 66 records.
10% spare paper = 6.6 → 7 sheets; total 73.
Displacement: 11 × 2 × 50 = 1,100 mL.
Liquid tests: 11 × 2 × 50 = 1,100 mL.
Base water = 2,200 mL.
10% reserve = 220 mL.
Prepare 2,420 mL (2.42 L), plus separate washing/rinsing water.
Extra sets carry the same run allocation and may support demonstration or pilot work. Reserve water does not add equipment sets. Additional specimens, different liquids, larger cylinders, overflow cans, spare apparatus, shared-balance scheduling and drying materials must be planned separately. The preparation calculator does not calculate density, verify full immersion or determine instrument uncertainty.
Staff must check actual sample compatibility, glassware condition, safe lowering/retrieval, instrument suitability, wet/dry bench layout and local disposal arrangements. The general risk-assessment framework is supplied by HSE; it does not approve this station. [7] No member-only CLEAPSS procedure or manufacturer instructions for the school’s equipment were reviewed for this draft. A physical pilot and technical review remain separate from the public-source check.
Public sources checked 15 October 2026. Source-derived methods and the editorial preparation choices are distinguished above.
No external source organisation has approved this guide. Historical safety-check dates on teaching resources are not validation of the adapted station.
Have feedback or a useful technician tip? Please contact us.
Draft prepared: 15 October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.
Build a matched density station around suitable specimens, readable length and volume measurements, and a balance with enough capacity. Check sample dimensions, cylinder bore, graduations and the locally approved method before ordering.
Links open in a new tab or window. These are catalogue searches, not verified product matches or current-stock guarantees. Displacement cans and micrometers are optional alternatives, not included in the base quantities. A specimen described as a density sample is not automatically suitable for water immersion or for the cylinder you have.