A quick-reference, four-chart guide for technicians preparing a GCSE transformer investigation: what to issue, how to connect two voltmeters, how to compare approved winding combinations and what to check before reuse. For more detailed curriculum practical resources, visit our Curriculum Experiments resources.
Check ratings → assemble unpowered → measure both voltages → change taps → repeat and compare

One reusable transformer station · repeat series reuse the core, windings and meters
One set has one fixed primary, one separate tapped secondary, one core and two AC voltmeters. Seven detachable leads are allowed: three for supply–switch–primary–return, two for the primary voltmeter and two for the secondary voltmeter.
One complete series covers every approved tap pair on one full record sheet. Extra sets receive the same repeat allocation. Spare leads and sheets are rounded up separately across the class. Replacement coils, additional current monitoring, alternative connectors, optional loads, electrical capacity and person-based PPE are not calculated. Settings and ticks are not saved.
Planning issue: 10 working stations + 1 extra = 11 equipped sets; 3 complete tap-comparison series per set = 33 series. AC voltmeters: 22. Leads: 77 working + 16 spares = 93. Record sheets: 33 working + 4 spares = 37. Reuse the core and coils; supply protection, cooling time and electrical capacity are planned separately.
| Item / issue specification | Per equipped set | Class provision (11 sets) |
|---|---|---|
| 1 complete core set | 11 | |
| 1 | 11 | |
| 1 | 11 | |
| 1 | 11 | |
| 2 | 22 | |
| 1 | 11 | |
| 7 + class spares | 93 (77 + 16 spare) |
|
| 1 station kit | 11 kits | |
| 3 records | 37 sheets (33 + 4 spare) |
Book staff test equipment, any additional current monitoring, safe cooling space and person-based PPE. Confirm simultaneous class demand and the protection of each station.
Separate secondary coils need one of every chosen turn count per set, not one coil. Integral leads, a double-pole switch or additional meters change the seven-lead allowance.
Check every winding section · close the core · connect each voltmeter in parallel

Confirm coil IDs, the primary turn count and each approved secondary pair. Check the full winding and unused sections as well as the measured output; label limits and protect terminals.
With the output off, trace the primary loop and both parallel meter branches. Confirm AC voltage ranges, separate winding circuits and a fully closed, secured core.
Staff verify output voltage, primary current and heating for every approved configuration. Agree a readable input, on-time, cooling intervals and a shutdown response before issue.
| Part | Required check | Avoid |
|---|---|---|
| Core / windings | Core closed; coils supported; primary identity fixed. | Opening the yoke live or trapping insulation. |
| Supply / taps | Approved AC input; all secondary sections checked. | DC, mains, unchecked step-up or shorted taps. |
| Both voltmeters | AC volts; appropriate range; V/COM connections. | Current inputs, a series voltmeter or a shared-earth link. |
| Measurement | Same Np, frequency and core; record actual Vp and Vs. | Changing several factors or trusting the supply dial. |
Ns is the number of turns between the two terminals in use, not automatically the coil’s total turns. Confirm the manufacturer’s tap labels; do not add or subtract labels without checking their meaning.
The secondary has no lamp or resistor attached. Its high-input-resistance voltmeter still draws a small current. Keep meter loading and ranges suitable for the small AC signals; the primary can still draw current.
| Tap pair / Ns | Vp (V) | Vs (V) | Ns/Np | Vs/Vp | Notes |
|---|---|---|---|---|---|
| A: ____ / ____ | ____ | ____ | ____ | ____ | ____ |
| B: ____ / ____ | ____ | ____ | ____ | ____ | ____ |
| C: ____ / ____ | ____ | ____ | ____ | ____ | ____ |
Primary ID / Np: __________ Frequency: __________ Meter ranges: __________
Use measured AC voltage magnitudes consistently. Ratio calculations require a valid, non-zero Vp.
Check AC, terminal pairs and core closure first · switch off before any adjustment
| Problem | What to check | Technician action |
|---|---|---|
| Little or no secondary voltage | DC selected, open winding, wrong meter mode, loose lead or incorrect taps. | Switch off. Staff trace the circuit and use known-good equipment; do not simply increase the input. |
| Voltage ratio far from prediction | Wrong turn count, poor core closure, unsuitable meter range/loading or changed Vp. | Verify the connected turns and record both voltages. Reassemble only with power off; retain anomalous readings. |
| Input falls or protection trips | Incorrect primary, unsuitable frequency/input, shorted turns, open core or accidental load. | Switch off and isolate for staff checks. Never bypass protection or fit a larger fuse to force a result. |
| Readings drift between repeats | Warming, supply variation, loose contacts or changed core position. | Follow cooling/reset rules, restore the layout and remeasure Vp. Report repeat spread rather than selecting a preferred value. |
| Unexpectedly high output / overrange | Unapproved tap pair, windings exchanged or full secondary turns overlooked. | Switch off immediately if safe. Staff reassess every winding section before reconnecting; do not probe at random. |
| Hot coil/core, smell, damage or loud new vibration | Excess input/on-time, saturation, damaged insulation or loose clamping. | Switch off if safe, keep clear and alert staff. Allow cooling, remove faulty kit and record the fault. |
Reference check: 21 October 2026. AQA curriculum [1] [8]; PHYWE and UNSW transformer background [2] [3]; Fluke voltage inputs [4]; HSE electrical precautions [5] [6]; PASCO power distinction [7]; PHYWE core-opening warning [9]. Full source notes are below the printable area.
The tapped-secondary issue, seven-lead circuit and repeat allocation are editorial choices requiring local approval and a complete pilot. No external organisation has approved this guide.
Explore buying guides, practical resources and laboratory reference information.
This Technician Practical Essentials guide brings together apparatus issue, transformer preparation, AC-voltage measurements, ratio comparisons and clear-down for school science technicians. It complements our Curriculum Experiments resources.
Source basis and adaptation: the established P01/P20–P23 template supplies the layout, calculator approach and four-chart print format. Transformer content is newly written using the references below. The fixed-primary/tapped-secondary route, two meters, seven leads and repeat allocation are preparation choices, not a verbatim source procedure or a validated kit specification.
A varying magnetic flux links two windings. With an AC-driven primary and suitable core, a secondary voltage is induced. The ideal relationship is Vs/Vp = Ns/Np; this guide compares measured magnitudes with that model. [1] [3] The specified AQA mapping is separate Physics, Higher Tier. Check other qualifications independently.
The base method changes only the connected secondary turn count, using several approved taps while retaining the primary, core and frequency. PHYWE describes related open-circuit voltage comparisons. [2] The seven-lead count assumes a separate primary switch and two independent voltage meters; it does not include a current-monitoring branch.
Turns ratio k = Ns/NpMeasured ratio q = Vs/VpBoth ratios are dimensionless. The ideal comparison is q = k. At fixed Vp, secondary voltage is predicted to increase with secondary turns. [1]
Use each row’s actual Vp; reject a ratio calculation when the input is zero, invalid or unresolved. Plot q against k and keep every point. Do not force measured results onto the ideal line or replace them with predicted values.
Arithmetic illustration only — not settings or observed data: for Np = 400, Ns = 200 and measured Vp = 2.00 V, the ideal prediction is Vs = 1.00 V. An illustrative measured 0.96 V would give q = 0.48 against k = 0.50. The 4% relative ratio difference is not a transformer efficiency.
A tap gives access to part of a winding; another section may have a larger induced voltage. Staff should identify all winding sections and estimate the highest output using the largest relevant turns ratio, then verify the actual arrangement within approved limits. This is an application of the turns-ratio model, not a guarantee that a calculated value establishes safety. [1] [2]
For a first issue, staff can restrict the tap list to step-down or equal-turn comparisons. A step-up example needs a separately checked voltage envelope, meter range and winding rating. Do not simply exchange coil roles: the new primary must suit the applied voltage and frequency. [3] Never use an exposed mains winding or a high-turn coil that can generate an unapproved output. Leave unselected taps unconnected and protected, not linked together.
The method calls for an isolated, protected low-voltage sinusoidal AC output and a compatible transformer kit. A supply with both AC and DC terminals must be connected to the correct output. No DC comparison is included. Staff approve the actual voltage, frequency, current protection and operating duration.
Use the AC voltage function and voltage input sockets. A meter lead left in an A/mA socket can short the circuit when connected across a winding. [4] Check low-voltage resolution and frequency suitability; use independent battery-powered meters or an approved isolated measurement arrangement.
Keep the core closed while powered. Opening the magnetic path can increase primary current. [9] The core condition is a controlled factor here, not an invitation to lift the yoke during operation. Any core-comparison demonstration needs a separately assessed method, with power off for every change.
The secondary is unloaded apart from its voltmeter, while the primary can still draw an excitation current. A close voltage-ratio match does not demonstrate zero losses. Real efficiency compares useful output power with input power under defined load conditions; AC phase relationships matter. [3] [7]
Do not treat Vrms × Irms as measured real input power without checking the conditions. An approved loaded extension needs suitable loads and instruments and a method that accounts for power factor; it is not obtained by adding an ammeter to this issue. [7]
| Variant | What changes | Preparation consequence |
|---|---|---|
| Change input voltage | Keep the same winding pair; compare several approved inputs. | Recheck every possible secondary voltage; record actual input each time. |
| Separate secondary coils | Replace a tapped coil with different complete secondaries. | Add all required coils, label turns and repeat core assembly checks with output off. |
| Step-up / load / core comparison | Changes the voltage envelope, load or magnetic circuit. | Use a new approved method and pilot; add rated components and instruments. No mains or short-circuit tests. |
The fixed example below uses 10 working stations + 1 extra complete set, three full tap-comparison series per set, 20% spare leads and 10% spare record sheets. The live calculator updates Chart 2, not this explanatory example.
10 + 1 = 11 equipped sets.
Two meters per set = 22 AC voltmeters.
7 × 11 = 77 working leads.
20% × 77 = 15.4 → 16 spare leads.
Total: 93 leads.
3 × 11 = 33 complete series.
One full sheet per series = 33 sheets.
10% × 33 = 3.3 → 4 spare sheets.
Total: 37 series-record sheets.
Reusable equipment is not multiplied by repeats.
One primary and one tapped secondary per set means 11 of each coil, not 11 of every possible tap. A different design may require more coil bodies or leads. The calculator does not predict safe input settings, output voltage, primary current, heating, available services or the time needed for cooling.
Checked 21 October 2026. These references support the stated principles; they do not approve this assembled classroom method.
No member-only CLEAPSS procedure or instructions for the school’s actual transformer kit were reviewed. Before issue, trained staff must check current authorised guidance and the actual manufacturer instructions, approve the local risk assessment and pilot every configuration. The source organisations have not endorsed this guide.
Have feedback or a useful technician tip? Please contact us.
Draft prepared: 21 October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.
Build the issue around compatible transformer coils and a closed core, an isolated low-voltage AC source, appropriate protection and two suitable AC voltmeters. Confirm tap counts, frequency, winding ratings and all possible outputs before ordering. This is not a pre-approved kit.
Links open in a new tab or window. These are catalogue searches, not verified product matches or current-stock guarantees. Confirm low-voltage AC output, protection, coil/core compatibility, voltage-meter suitability and connector counts. Do not substitute a DC-only supply, an autotransformer or a mains-connected experimental winding.