Login

Skip to the practical guide

Better Equipped Technician Practical Essentials

Investigating the resistance of a wire

Change the active wire length, measure voltage and current, and keep temperature change small

A quick-reference, four-chart guide for technicians preparing a wire-length investigation: what to issue, how to define the measured section, which readings to record and how to reset safely. For fuller curriculum practical resources, visit our Curriculum Experiments resources.

GCSE PhysicsWire length and resistanceP18 · Supporting practicalv1.0 October 2026

Print all four charts on A4 portrait. Choose Save as PDF or your printer in the print window. Use 100% scale and turn off browser headers and footers.

To print, use your browser’s Print command: Ctrl+P (Windows) or Cmd+P (Mac).

Scope: one uniform wire, one material and diameter, and a series of non-zero contact separations. This supports the wire-length element of AQA Physics required practical 3 and Trilogy required practical 15. Those activities also include resistor combinations, which are not covered by this guide alone. [1] [2]

P18 is a Better Equipped supporting-guide code, not “required practical 18”. It develops the wire work introduced in P03; P17 covers series/parallel measurements and P04 covers I–V characteristics. The seven-lead layout, 1.10 m wire cuts and calculator defaults are editorial preparation choices. Staff must approve the actual wire, current-limiting arrangement, minimum length and reading/cooling routine.

One identified wireKeep material and diameter unchanged
Measure between contactsL is X–Y, not the whole cut
Measure actual V and IVoltmeter spans the active section
Limit temperature changeLow current; brief readings; cooling
Repeat the full seriesRecheck a reference length for drift
Better EquippedTechnician Practical EssentialsP18 · GCSE Physics

Investigating the resistance of a wire

The practical at a glance

Define X–Y → measure paired V and I → switch off → compare resistance with length

Investigating the resistance of a wire methodology
One wiresame alloy, diameter and specimen
R = V / Ivolts ÷ amperes = ohms (Ω)
Power off to movenever bring live contacts together
Selected method: change the length between a fixed contact X and movable contact Y. Measure V across those same contacts and I in the feed. Keep the separate current limiter outside X–Y. Start with the longest approved length.
  1. Approve and pilotInspect the wire, support, contacts and meters. Trial the full length range, especially the shortest span. Agree current, brief on-time, cooling and stop limits; check that the smallest voltages are readable. [4] [7]
  2. Mount and identifySecure one straight wire beside a fixed metre rule on a non-conducting support. Do not stretch it. Label the specimen, alloy and diameter. Keep loose tails and sharp ends clear of other conductors.
  3. Connect with output offConnect DC (+) → switch → ammeter → separate current limiter → X → wire → Y → DC (−). Connect the voltmeter across X–Y only. Staff check sockets, ranges, polarity and protection.
  4. Define the first lengthRecord both contact positions and their separation. A possible planning range is 100, 80, 60, 40 and 20 cm, subject to the actual-kit pilot. Never test zero separation; keep the voltmeter connected to the same two endpoints.
  5. Read, switch off, resetAt each length, take a stable paired V and I reading promptly, then switch off. Allow the agreed cooling before moving Y. Keep the wire and contact convention unchanged; record any setting changes or drift. [5] [6]
  6. Recheck and repeatReturn to the first reference length and repeat its measurement after cooling. Retain any difference. Then repeat the complete length series after reset, keeping a separate record; repeated display readings are not independent runs.
  7. Calculate and compareConvert mA to A; calculate R = V/I for every resolved, non-zero current reading. Plot R (Ω) vertically against L (m) horizontally. Compare repeats at the same length; retain offsets and exclusions rather than forcing agreement. [3]
Low voltage can still produce hot wire and shorts. Never put an ammeter across the supply or X–Y, bypass the limiter, move powered contacts or test temperature by touch. Stop for heating, excessive current, smell or damage; switch off if safe and alert staff.
Better EquippedTechnician Practical EssentialsP18 · GCSE Physics

Apparatus and materials

One reusable wire station · complete series multiply records, not equipment

 
Interactive calculator not active. Fixed example: 10 stations + 1 extra; five lengths and three full series per set; 20% spare leads, 10% spare wire and 10% spare paper. Prepare 11 sets, 93 leads, 13 wire cuts (14.30 m) and 37 record sheets. Adjust manually when scripting is unavailable.

Planning issue: 10 working stations + 1 extra = 11 equipped sets. Five distinct lengths + 1 reference recheck per series; 3 full series per set = 33 records and 198 planned V–I pairs. Leads: 77 working + 16 spares = 93. Wire: 11 working + 2 spare = 13 cuts of 1.10 m; 14.30 m before cutting waste. Paper: 33 records + 4 spares = 37 sheets. Reuse sound wire and apparatus after cooling/reset; counts do not set safe electrical limits.

Tick prepared items. Spare wire cuts do not create extra stations; protection and meters are reusable.
Item / issue specification Per equipped set Class provision (11 sets)
1 11
1 of each 11 of each
1 11
1 11
1 complete kit 11 kits
1 cut + class spares 13 cuts
(11 + 2 spare)
14.30 m total
2 22
7 + class spares 93 leads
(77 + 16 spare)
1 connection kit 11 kits
1 11
3 / set 37 sheets
(33 + 4 spare)

Prepare separately

Labels, approved circuit card, suitable fixings/tape, cutters, staff check equipment, replacement fuses and assessed PPE. Micrometer work and different wire materials are optional additions.

Counts are not operating limits

The calculator does not select voltage, wire diameter, minimum separation, limiter resistance, power rating or cooling time. Confirm class service capacity and the actual connector layout.

Better EquippedTechnician Practical EssentialsP18 · GCSE Physics

Preparation and apparatus set-up

Keep the same two endpoints for length and voltage · exclude the limiter from the measured span

Investigating the resistance of a wire set up

1 · Identify and mount

Check wire identity, uniformity and damage. Mount it straight without tension and keep the ruler fixed. Decide one repeatable contact-position convention; do not use the jaw’s plastic housing as the endpoint.

2 · Trace and check

With output off, check the complete loop, meter sockets and shared X/Y connections. Keep the high-input-resistance voltmeter across the active section; never use an Ω function on a powered circuit.

3 · Pilot the extremes

Check the shortest and longest planned spans for current, heating and readable voltage. Agree brief reading, cooling and a reference-return check. A steady display alone does not prove constant temperature.

Series path: DC (+) → switch → ammeter → current limiter → X → tested wire → Y → DC (−).
Voltage: across X–Y only; exclude the limiter, switch and ammeter.
Length: L = |xY − xX|. Move Y and its voltmeter connection together, with output off.
Check the measured section before every reading
Part Required arrangement Avoid
Wire and tails Same specimen, material and diameter; only active length changes. Stretching, kinks, a new wire midway or a connected free tail.
Contact positions Read the actual contact locations; start with the longest approved span. Zero separation, broad inconsistent contacts or measuring the whole cut.
Meter connections A in the feed; V on the same X–Y endpoints. Check actual V and I. Using the supply dial as wire voltage or including the limiter in V.
Temperature routine Low current, brief stable readings, output off and cooling; recheck reference. Leaving power on between lengths or touching the wire to test heat.
One full-series record — expand for every length and reference recheck
Point / stage xX / cm xY / cm L / m V / V I / A R / Ω; notes
1 · Reference ____ ____ ____ ____ ____ ____
2 · Length ____ ____ ____ ____ ____ ____ ____
Further lengths ____ ____ ____ ____ ____ ____
Return to reference ____ ____ ____ ____ ____ ____

Record wire ID/alloy/diameter, series ID, meter ranges and original display units. Convert position differences from cm to m and current from mA to A. Retain supply/limiter settings, cooling notes and all raw readings.

The return check is diagnostic, not a correction. A changed R at the same length may indicate heating, contact movement or another fault. Retain both values and investigate. Do not alter measurements to recover an expected straight line.
Min./max. L: __________Supply / current / limiter: __________On-time / cooling: __________Wire / pilot / staff check: __________
Better EquippedTechnician Practical EssentialsP18 · GCSE Physics

Troubleshooting and clear-down

Check endpoints, temperature and units first · switch off before changing anything

Problem What to check Technician action
No current or a zero display Open circuit, incorrect socket/range, poor contact, failed fuse or an unsuitable display resolution. Switch off and trace the circuit. Staff check the meter. Do not bypass a fuse or increase voltage blindly.
High current, heating or drifting values Too-short span, incorrect limiter, a wire bypass or prolonged energising. Switch off if safe, keep clear and alert staff. Inspect cold and re-pilot. Do not move live contacts or cool with water.
R changes at the same length Wire heating, shifting/wide jaws, stretching, a kink or a different specimen. Cool and reset using the same contact convention. Record the reference recheck and retain the original data.
Resistance is unexpectedly large or small Wrong voltmeter span, mA treated as A, V/I inverted or near-zero readings. Check the raw pair and units. Do not divide by zero; a zero current display is not evidence of zero resistance.
R–L graph misses the origin Contact contributions, length offsets, temperature change, meter loading or limited resolution. Use a justified fit and inspect the intercept. Do not invent a measured point at L = 0 or force the line through zero.
Repeats disagree or pattern is weak Inconsistent contact placement, poorly resolved short spans, changed settings or cooling. Compare the spread at each length. Re-pilot unsuitable ranges; label invalid data and explain exclusions.
Interpret the pattern: for a uniform wire of unchanged material and cross-section at stable temperature, resistance increases with length. Calculate each paired V/I first, then compare repeated values at the same length. A length investigation is not, by itself, an I–V test of Ohm’s law. [4] [5]
Current: mA ÷ 1,000 → ALength: cm ÷ 100 → mGraph: R (Ω) on y; L (m) on x
Power off does not mean cool to touch. Allow the approved cooling before handling wire or the limiter. Never leave the circuit energised unattended, pull on damaged leads or attempt live repairs.

Clear-down and reset

01 · Switch off and retainIsolate as instructed. Keep wire ID, contact positions, V–I pairs, ranges, reference checks and exclusion reasons together.
02 · Cool and inspectCheck wire, contact jaws, mounts, leads and limiter. Keep damaged specimens separate; a replacement needs a new ID and full record.
03 · Store without strainProtect sharp ends and avoid stretching or tight kinks. Return counted leads and contacts; restore meter storage settings and leave the supply off.
Prepared by: __________Method / assessment: __________Condition / cooling check: __________

Public references checked: 21 October 2026. AQA scope and equations [1] [2] [3]; related IOP wire and V–I activities [4] [5] [6]; general HSE electrical guidance [7]. Full references and source/adaptation notes are below the printable area.

The station counts, contact convention and reference recheck are editorial choices requiring local review and a complete pilot. No external organisation has approved this guide.

More practical support from Better Equipped

Explore buying guides, practical resources and laboratory reference information.

Visit Better Resources →

About this guide

This Technician Practical Essentials guide brings together apparatus issue, wire mounting, contact-to-contact length measurement, paired voltage/current readings and safe reset. It complements our Curriculum Experiments resources.

Source basis and adaptation: P17 supplies the established page style, preparation calculator behaviour and four-chart format. The wire method builds on P03’s wire-length route and the public teaching sources below. AQA establishes the required-practical scope; IOP describes related wire and V–I investigations. [1] [2] [4] [5] [6] The dedicated wire station, seven-lead allowance, five-length example and end-of-series reference check are editorial preparation choices, not a verbatim source procedure or a validated kit specification.

Curriculum scope and overlap

P18 is a focused supporting guide for resistance versus length. It addresses the wire-length element of AQA Physics required practical 3 and Trilogy required practical 15, but does not replace their resistor-combination work. P03 brings both elements together; P17 develops current and voltage measurements in series and parallel. P04 investigates I–V characteristics at a chosen component, which asks a different question. [1] [2] Check the specification used by your centre before mapping this guide to another awarding organisation.

Define the wire section, not the whole specimen

The specimen can extend beyond both contacts, but only the section between X and Y is intentionally in the current path. Both voltmeter branches use those same endpoints. The position convention should identify the jaw–wire contact, not the plastic clip body. A broad jaw, changing grip or an uncertain contact point contributes to length uncertainty. Keep unused tails electrically free, clear of each other and safely retained.

Preparation example, not a prescribed range: a 1.10 m cut can allow a 1.00 m tested span plus short fixing tails, only when the actual mounting permits it. The example sequence of 100, 80, 60, 40 and 20 cm is not automatically safe or measurable with every alloy, diameter and supply. Record the actual contact separation rather than substituting the intended value. A reference contact need not coincide with the ruler’s zero.

Length and units

L = |xY − xX|Use a consistent reference at each contact. Convert cm to m before plotting in SI units; the graph’s gradient then has units Ω/m. Never energise the circuit with coincident contacts.

Resistance from a measured pair

R = V / IUse V across X–Y and I from that reading. Convert mA to A first. A zero or unresolved current is not a valid denominator. The supply setting is not the measured voltage across the wire. [3] [6]

Temperature control and electrical limits

The intended comparison changes length while keeping material, diameter and temperature sufficiently stable. Short spans can draw excessive current; IOP highlights heating and the value of low-current, short-duration readings. [4] [5] For this adaptation, staff set the supply/current limit and separate limiter using the actual kit, then trial the complete range. A suitable rheostat or fixed resistor assembly must have adequate current/power capacity; never assume its name or the supply’s low-voltage label establishes safety.

Readings should be brief but settled enough to resolve both meters. Switch off and use the approved cooling routine before moving the contact. Return to the initial reference length after the series to look for drift. Agreement is reassuring but does not prove the wire stayed at exactly constant temperature; disagreement can also come from contacts, meter behaviour or mechanical changes. Constantan’s name does not establish temperature independence.

There is no requirement in this guide to hold the supply dial, measured current or measured wire voltage artificially identical at every length. Any adjustment must follow the approved method and be recorded; each resistance comes from its own V–I pair. Keep the intended low-power regime comparable. The core method does not use water cooling, a bare copper short, or high-current heating.

What the meter pair actually measures

Measurement-model note: with A upstream of the voltmeter branch, the ammeter reads wire current plus the small current drawn by V. If the voltmeter input resistance is RV, the idealised indicated V/I is the parallel combination of the tested path and RV. A sufficiently high RV makes this contribution small. This is a circuit-model explanation, not a correction to apply blindly to classroom data.

The two-contact arrangement is not a four-terminal precision resistance measurement. Contact contributions inside the sensing points and uncertain effective length can matter, especially when the wire voltage is very small. A non-zero graph intercept may be consistent with such effects, but cannot identify their cause by itself. Do not subtract an assumed contact resistance to make the results agree.

Plotting, repeats and interpretation

Use resistance vertically and measured length horizontally. Calculate R for every original pair, then compare valid repeats at the same length. Report the arithmetic mean of those calculated resistances and their spread when appropriate; do not silently replace it with mean voltage divided by mean current. Keep the return-to-reference check identifiable rather than counting it as another distinct length or an independent full repeat.

The uniform-wire model predicts proportionality between R and L when the other relevant properties remain fixed. [4] Keep an unconstrained, justified best fit and examine the intercept; a physically measured zero-length point would be a short circuit, not a useful data point. Different wire identities should not be pooled as repeat measurements of one specimen.

Ohm’s law is a different test. A resistance value is defined from V/I at a point; a linear I–V response requires an appropriate constant-condition investigation. Changing length while taking one V–I pair at each length does not establish that a single length is ohmic. [5]

Optional extensions — outside the base issue

Material or diameter comparisons require new labelled specimens, controlled lengths and fresh checks of safe current and measurement resolution. A department extending to resistivity may use R = ρL/A for a uniform wire; deriving ρ from an R–L gradient also requires an independently measured cross-sectional area. That is not what the base preparation calculator or core record determines. [4] An ohmmeter route is another separately approved method; never connect a resistance-function meter to this powered V–I circuit.

Worked preparation example

The example below stays fixed: 10 working stations + 1 extra set; five distinct lengths; three complete series per set; 20% spare leads, 10% spare wire cuts and 10% spare paper. The live calculator changes Chart 2, not these explanatory figures.

Reusable equipment and leads

10 + 1 = 11 complete stations.
Two contacts per set = 22 contacts.
7 × 11 = 77 working leads.
20% × 77 = 15.4, rounded up to 16 spares.
Total = 93 leads. Check the actual connection style.

Wire cuts and stock length

11 working cuts + ceiling(10% × 11) = 13 cuts.
13 × 1.10 m = 14.30 m before cutting waste.
Spare cuts do not add stations. Reuse sound wire after checks; a changed specimen needs its own identity.

Complete series and paper

11 × 3 = 33 complete-series records.
10% × 33 = 3.3, rounded up to 4 spare sheets.
Total = 37 record sheets.
Each sheet includes every length plus the return check.

Reading workload, not extra apparatus

5 length points + 1 reference recheck = 6 paired readings per series.
33 × 6 = 198 planned V–I pairs.
Extra fault investigations, invalid-reading replacements and separate student worksheets need their own allowance.

Local approval and review

Review the actual supply, meters, leads, limiter, wire and contact fittings against current authorised school-science guidance and manufacturer instructions. Agree isolation, faults, cooling, sharp-end handling, supervision and assessed PPE. HSE provides general electrical-safety guidance, not approval of this station. [7]

No member-only CLEAPSS procedure or manufacturer instructions for the school’s actual equipment were reviewed for this draft. Public-source checking is separate from technical review and a physical pilot. Historical safety-test dates on teaching activities do not validate this adaptation.

Have feedback or a useful technician tip? Please contact us.

Draft prepared: 21 October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.

Everything you need for this practical

Build a compatible wire station around the actual resistance wire, contacts, protection and readable voltage/current measurements. Check ratings, mounting span and the locally approved method before ordering.

Supply, measurement and protection — catalogue searches

Wire, contacts and preparation — catalogue searches