Login

Skip to the practical guide

Better Equipped Technician Practical Essentials

Investigating sound waves

Comparing frequency and signal amplitude with a microphone and oscilloscope

A quick-reference, four-chart guide for technicians: what to issue, how to obtain a clear sound trace, how to organise fair comparisons and how to reset safely. For more detailed curriculum practical resources, visit our Curriculum Experiments resources.

GCSE PhysicsSound · frequency and amplitudeP26 · Technician referencev1.0 October 2026

Print all four charts on A4 portrait. Choose Save as PDF or your printer in the print window. Use 100% scale and turn off browser headers and footers.

To print, use your browser’s Print command: Ctrl+P (Windows) or Cmd+P (Mac).

Scope: a low-level, sine-tone investigation using a loudspeaker, one microphone and a time-domain oscilloscope. It supports wave-property work; it is not an additional named AQA required practical or a substitute for required practical 8. [1] [12] P26 is a Better Equipped planning code. The comparison sequence and quantity allowances are editorial choices. Sound levels, timings, equipment compatibility and access arrangements require a local pilot. Wave-speed measurements, hearing tests and calibrated decibel measurements are outside the core method.
Keep sound lowBrief tones; agree limits and quiet intervals
Fix the geometrySame microphone position and direction
Read both axesTime horizontally; microphone signal vertically
Separate the controlsFrequency series, then source-level series
Retain the settingsNo hidden gain, scale or range changes
Better EquippedTechnician Practical EssentialsP26 · GCSE Physics

Investigating sound waves

The practical at a glance

Pilot quietly → stabilise the trace → vary one control → measure, reset and repeat

Investigating sound waves methodology
One fixed microphonekeep position, direction and gain unchanged
T = Δt / n; f = 1 / Tmeasure complete cycles; use seconds
Two comparisonschange frequency OR source level
Worked approach: Use a sine-wave signal generator with a compatible speaker/driver, and a microphone with any required preamplifier feeding the oscilloscope. Record the microphone signal, not just the generator output. [2] [7]
  1. Approve and pilotCheck every signal path and support. Agree the tone range, maximum source setting, brief sounding time and quiet intervals. Trial a clear trace at low sound level; organise one active station at a time where needed.
  2. Connect and positionWith outputs off, connect the matched generator/speaker path and the separate microphone/display path. Mark the microphone distance, height and direction. Start with the source level at minimum; keep listening or monitoring feedback disabled.
  3. Establish a baselineSelect a sine tone and raise output only to the approved low level. Set a stable trigger and scales that show several unclipped cycles. Record time/division, signal scale, microphone gain and source settings; capture the baseline. [5]
  4. Compare frequenciesChange only the generator’s frequency through the approved settings. Keep geometry and gain fixed; record any display-scale change. Measure each period from complete cycles. A fixed output dial does not guarantee equal acoustic amplitude at different frequencies.
  5. Compare source levelsRestore one agreed frequency. Change only source-output level within the approved limits. Keep microphone gain, position and display scales unchanged. Record peak-to-peak microphone signal and confirm the period remains similar; stop before clipping.
  6. Reset and repeatMute between observations. Restore the baseline and repeat both comparisons; three complete sequences per set is the planning example. Keep every trace, reading and setting; repeats reuse the same equipment.
  7. Interpret the tracesCalculate T and f; compare period and signal height separately. The horizontal axis is time, not distance. A microphone time trace does not show the spatial shape of the sound wave, and its height is not automatically a decibel value. [3] [6]
Sound and access: keep ears away from the speaker and use short, low-level tones. No headphones, shouting or hearing-limit challenges are part of this method. Stop for discomfort, feedback or an unexpected loud tone. Agree an equivalent visual observation route; do not rely on discomfort as a safety test. [8] [9]
Better EquippedTechnician Practical EssentialsP26 · GCSE Physics

Apparatus and materials

One reusable sound station · repeats multiply observation sheets, not instruments

 
Interactive calculator not active. Fixed example: 10 stations + 1 extra set, three sequences per set, 20% spare speaker leads and 10% spare sheets. Prepare 11 complete sets, 27 speaker leads, 11 microphone cable kits and 37 record sheets. Adjust manually when scripting is unavailable.

Planning issue: 10 working stations + 1 extra = 11 equipped sets; 3 complete sequences per set = 33 sequences. Speaker leads: 22 working + 5 spares = 27. Microphone cable kits: 11. Sheets: 33 working + 4 spares = 37. Acoustic scheduling, mains capacity and extra accessories are planned separately.

Tick prepared items. Equipment is reused; a prepared station is not permission to sound every station simultaneously.
Item / issue specification Per equipped set Class provision (11 sets)
1 11
1 complete unit 11
1 complete path 11
1 11
2 + class spares 27
(22 + 5 spare)
1 kit 11 kits
1 support kit 11 kits
1 11
3 sheets 37
(33 + 4 spare)
Plan separately Shared / person-based

Check the actual connectors

Some generators need an amplifier to drive a loudspeaker; some microphones need power or a preamplifier. Count the complete working system, not just four separate instruments.

Plan the room, not just the kit

Several simultaneous tones can mask each other. Book quiet turns, space and accessible display viewing; add all power accessories and check electrical-service capacity separately.

Repeat basis: Reusable equipment and microphone kits are counted once per equipped set. Repeats increase record sheets only. Extra sets are available sets, not automatically extra live sound sources.
Better EquippedTechnician Practical EssentialsP26 · GCSE Physics

Preparation and apparatus set-up

Match the source and detector · fix the geometry · pilot both comparisons

Investigating sound waves set up

1 · Match and inspect

Check ratings, signal levels, leads, microphone power and support. Confirm the source can drive the speaker and the microphone path gives a readable signal.

2 · Fix and label

Mark distance and direction. Use the microphone channel, not a generator reference trace. Label time/voltage units; fix gain and disable automatic level changes where possible.

3 · Pilot both comparisons

Check several frequencies and source levels quietly. Choose scales that avoid clipping. Record limits, timing and the room plan; allow visual participation without listening.

Source: sine-wave generator → compatible speaker/driver → sound through air.
Detector: microphone → required preamplifier → oscilloscope input. There is no electrical wire across the air gap and no microphone-to-speaker feedback path.
Checks before the first trace
Part Required check Avoid
Source / room Low approved output; fixed sine waveform; only agreed stations sounding. A loudness contest or an untested speaker load.
Microphone / display Fixed geometry and gain; stable trigger; visible, unclipped cycles. Automatic gain or scale changes that hide the comparison.
Readings / units Time/division and signal units retained with every trace. Calling horizontal spacing wavelength or voltage decibels.

Period and frequency

Measure elapsed time Δt across n complete cycles:T = Δt / n   ·   f = 1 / TCount cycle intervals, not the number of peaks. Convert ms to s before calculating Hz. [1] [4]

Signal size

Vpp = Vmax − VminUse the effective input scale, including any probe factor. For a symmetric sine trace, peak amplitude is Vpp/2; this is signal voltage, not calibrated sound pressure. [4] [6]

Recording prompt — expand on a full sheet for each complete sequence
Condition / source setting n cycles / Δt / units T (s) / f (Hz) Vpp / units / notes
Baseline ____ / ____ / ____ ____ / ____ ____
Frequency changed ____ / ____ / ____ ____ / ____ ____
Source level changed; f fixed ____ / ____ / ____ ____ / ____ ____
Baseline restored ____ / ____ / ____ ____ / ____ ____

With every trace: time/division, signal scale, gain, position and sequence ID. Use the display’s actual units; an uncalibrated interface may show arbitrary units, not volts.

Approved tones / level: __________Position / gain: __________Timing / pilot: __________
Better EquippedTechnician Practical EssentialsP26 · GCSE Physics

Troubleshooting and clear-down

Check the signal path and scales first · preserve settings · keep sound exposure low

Problem What to check Technician action
No trace or very weak response Wrong channel, muted output, microphone power/preamp, cable or sensitivity. Mute the source. Check the detector path and a known-good component; do not simply turn up the speaker.
Trace drifts or will not settle Trigger source/level, timebase, background sound or several stations playing. Use one source; adjust the trigger and timebase, then record the settings. Check for a repeating clean signal.
Flat-topped or distorted trace Source, amplifier or microphone overload; display range or input clipping. Reduce source level or approved input gain and re-pilot. A larger screen range alone cannot cure an overloaded microphone.
Height stays constant or changes unexpectedly Automatic gain, autoscale, normalisation, moved microphone or altered gain. Restore a fixed-gain path and position. Retake affected comparisons; do not compare screen heights at different scales.
Period or frequency looks wrong Milliseconds used as seconds, half-cycles counted, wrong trace or insufficient sampling. Count several full cycles. Check axis units and acquisition settings; retain the original reading and explain any correction.
Unexpected loud tone, feedback or distress Monitoring loop, output jump, another sound source or unsuitable settings. Mute promptly and pause the activity. Staff review the setup and access arrangements before restarting; no ear-close checks.
Interpret the comparison: Higher frequency corresponds to a shorter period. At fixed frequency and with an unchanged detector path, changing the source level can change the trace height. Keep these observations separate; changing volts/division changes the display, not the sound. [3] [5]
Do not infer a safe sound level from the waveform. Use the local sound-exposure assessment; quiet gaps and short recordings do not by themselves prove safety. Keep user connections to approved low-voltage signal paths. Never probe mains or defeat an oscilloscope’s protective earth. [8] [9] [10]

Clear-down and reset

01 · Mute and retainReduce source output to minimum, mute and switch off as instructed. Keep traces with their axes, gain, geometry and sequence labels.
02 · Disconnect and inspectPower down before changing connections. Check plugs, microphone mounts and speaker cones; handle connectors, not cables.
03 · Store and recordReturn microphones and leads safely. Restore the agreed low-output startup settings, remove temporary recordings as required and log faults.
Prepared by: __________Method / assessment: __________Sound / access checked: __________

Reference check: 22 October 2026. AQA wave context [1] [12]; IOP sound/display guidance [2] [3] [7]; Tektronix and Vernier measurement distinctions [4] [5] [6]; HSE exposure and electrical guidance [8] [9] [10]. Full sources and optional routes are below the printable area.

The station design, lead allowance and two-part repeat sequence are editorial choices requiring local approval and a full pilot. No external organisation has approved this guide.

More practical support from Better Equipped

Explore buying guides, practical resources and laboratory reference information.

Visit Better Resources →

About this guide

This Technician Practical Essentials guide brings together apparatus issue, sound-level planning, microphone and display checks, controlled comparisons and clear-down for school science technicians. It complements our Curriculum Experiments resources.

Source basis and adaptation: the approved four-chart series template supplies the layout, infographic spaces, calculator behaviour and print approach. The sound-wave content is newly written using the public references below. The fixed-position, two-comparison sequence, repeat allowance and equipment counts are editorial preparation choices, not a verbatim source procedure or a validated kit specification.

Scope and curriculum context

The core route supports amplitude, period and frequency work and the distinction between longitudinal sound in air and a signal-versus-time display. AQA places its additional sound-transduction and hearing content in separate Physics, Higher Tier; that does not make all basic wave-property work Higher Tier. [1] This page is a supporting investigation, not an additional named required practical. AQA required practical 8 specifies ripple-tank waves and waves in a solid; this microphone activity alone does not replace it. [12] Check the centre’s own specification and practical programme.

What the instrument is showing

The microphone detects pressure changes at its location and produces an electrical signal. The horizontal axis records elapsed time, not distance along the room; peak spacing therefore gives a period, not a wavelength. The displayed curve does not mean that the air particles travel along a transverse sine-wave path. IOP explicitly cautions against these interpretations. [3]

The vertical reading depends on the microphone, preamplifier, position and acquisition settings. It can be quoted in volts only when the input scaling supports this; some educational interfaces use arbitrary waveform units. Neither a taller trace nor a larger voltage is automatically a calibrated sound-pressure level in decibels. [6]

Keep the two comparisons separate

Frequency comparison

Keep the same sine waveform, source-output setting, geometry and microphone gain while varying frequency. Read the period at every condition; record any necessary scale change. The speaker, microphone and room can respond differently at different frequencies, so do not claim equal loudness merely because the output dial was unchanged. [7]

Source-level comparison

Return to one frequency and hold it fixed. Vary only the source output within approved limits, using the same microphone position and fixed display/gain settings. Compare the signal size and period separately. Do not use automatic rescaling to make traces look equal; verify any processing in the actual system. [5] [11]

Worked reading examples

Frequency from several cycles

Arithmetic illustration, not observed data: five complete cycles span 10.0 ms.T = 10.0 ms / 5 = 2.00 ms = 0.00200 sf = 1 / 0.00200 s = 500 HzFive cycles require five equal-phase intervals: six consecutive peaks delimit five cycles. These numbers do not prescribe a tone or exposure level. [4]

Peak-to-peak signal

Arithmetic illustration: a trace spans 3.0 vertical divisions at an effective input scale of 0.050 V/div.Vpp = 3.0 × 0.050 = 0.150 VFor a symmetric sine trace, its peak amplitude about the midline is 0.075 V. Keep peak, peak-to-peak and RMS quantities distinct; no sound-pressure calibration is implied. [4]

Technical checks for a reliable display

Use calibrated time and voltage scales and a stable trigger. If a probe or adapter changes the scale, record the effective scale shown at the instrument input. A digital display needs sufficient sampling and a suitable record length for the chosen tones; follow its instructions rather than copying one universal rate. [5] A microphone output, preamplifier output and loudspeaker output are not interchangeable input levels: check the manufacturer’s connection diagram for the exact combination.

Disable automatic gain, noise suppression, normalisation or similar processing when using a software route for amplitude comparisons, where the system permits it, and verify the behaviour with the pilot. Browser microphone controls are not universally supported; requesting a fixed-gain setting is not proof that it took effect. [11] If fixed gain cannot be established, do not treat the displayed heights as a controlled amplitude comparison. Use a suitable hardware path or restrict the digital route to a checked frequency exercise.

Reflections and neighbouring stations can alter the signal. IOP’s sound-wave demonstration deliberately uses reflections to produce standing-wave maxima and minima; P26’s core sequence does not. [7] Keep the chosen position unchanged, document the room arrangement and avoid silently replacing unexpected readings with ideal sine curves.

Sound exposure and inclusive access

Staff should approve sound levels and duration for the actual room and group, considering all simultaneously operating sources. Use the lowest output that supports the measurement, short sounding intervals and quiet breaks; assess rather than guess the exposure. HSE describes controlling noise at source and organising work to reduce exposure. [8] [9] This guide does not set a universal decibel threshold or a maximum safe generator voltage.

The practical is not a hearing test. Do not ask learners to prove they can hear high-frequency tones, place their ears against a speaker or increase sound until someone objects. Agree a stop signal and visual participation arrangements in advance. Any local requirement for a suitable sound-level instrument or specialist support must be planned separately; the ordinary oscilloscope waveform is not that instrument.

Optional routes — add equipment and pilot separately

Tuning forks and timbre

A tuning fork and suitable resilient striker can provide another repeating sound; optional musical sources can show less sinusoidal waveforms. IOP describes these comparisons. [2] Inspect the fork and use its approved striker. Keep it away from faces and equipment; do not use it to strike the microphone. Retain the same scales and distinguish fundamental repetition from extra peaks.

Approved digital capture

A microphone/interface with a calibrated time axis may replace the oscilloscope under a locally checked method. Verify gain, sampling, units and clipping; add the interface/computer to the kit. Vernier’s sound-sensor documentation illustrates the distinction between waveform and sound-level channels, not compatibility with every system. [6]

Distance or room effects

A separate fixed-frequency distance series can examine how the detected signal varies. Retain orientation and gain, measure a defined separation and record reflections. Do not infer a universal inverse-square relationship from a few indoor voltage readings. The IOP sound-wave activity provides a related reflection/standing-wave context. [7]

Speed of sound

Use a separate approved method with a measured travel distance and delay, or a justified wavelength measurement. A one-position microphone trace supplies frequency, not wavelength or speed by itself. Keep wave-speed work distinct from this core sequence; the programme’s P08 and AP14 cover related measurement themes.

Worked preparation example

The fixed example below matches the initial calculator settings: 10 working stations + 1 extra complete set, three sequences per set, 20% spare speaker leads and 10% spare sheets. The live calculator updates Chart 2; this example does not change.

Equipment and signal connections

10 + 1 = 11 reusable equipment sets.
2 speaker leads × 11 = 22 working leads.
20% of 22 = 4.4, rounded up to 5 spares.
Total = 27 speaker leads.
Also issue 11 complete microphone cable/adapter kits. Count any extra driver or interface links separately.

Sequences and paper

3 complete sequences × 11 = 33 sequence records.
10% of 33 = 3.3, rounded up to 4 spare sheets.
Total = 37 full record sheets.
One sheet covers both comparisons and all their conditions. Additional learners’ worksheets are separate from this station-record allowance.

Extra complete sets receive the same repeat allocation as working sets. The calculator does not predict sound exposure, duration, suitable source settings, electrical-service demand or the number of stations that can operate without interference.

Have feedback or a useful technician tip? Please contact us.

Draft prepared: 22 October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.

Everything you need for this practical

Build the station around a matched sound source, a complete microphone signal path and a readable waveform display. Confirm output/load compatibility, microphone power, connectors, input ranges and local sound-level arrangements before ordering. This is not a pre-approved kit.

Sound sources and waveform measurement — catalogue searches

Connections, positioning and optional resources — catalogue searches