We use cookies to give you the best experience possible. By continuing to use the site, you indicate that you accept cookies. See our cookies policy here.
Better Equipped Technician Practical Essentials
A quick-reference, six-page guide for technicians preparing a GCSE simple-distillation practical: what to issue, how to arrange the heating and cooling, what to check and how to clear down. For more detailed curriculum practical resources, visit our Curriculum Experiments resources.

Heat gently · condense the vapour · collect a small sample · cool before dismantling

One complete reusable station · fresh solution and granules for each cold-start run
One set means one fully equipped distillation station. Extra complete sets include the selected run allowance. Each run starts with 50 mL fresh salt solution and one approved portion of fresh granules. Apparatus is cleaned, cooled and reused between runs.
Apply the solution allowance to 50 mL × runs per set; round up to 1 mL per set before multiplying. The granule count is portions, not individual granules or grams; staff specify the dose and add spares. Cooling-water consumption, electrical loading, service points, extra pilot work and cooldown scheduling are not calculated. Settings and ticks are not saved.
Interactive calculator not active. Fixed example: 10 stations + 1 extra set, two complete runs per set and 25% solution allowance. Provide 11 distillation assemblies, 22 coolant hoses, 1,375 mL salt solution and 22 approved granule portions, plus local spares. Adjust manually when scripting is unavailable.
Planning issue: 10 working stations + 1 extra = 11 sets; 2 complete cold-start runs per set = 22 runs. At 25% solution allowance, provide 125 mL salt solution per set: 1,375 mL for the class. Prepare 11 reusable distillation assemblies and 22 coolant hoses. Fresh anti-bumping granules: 22 approved portions, plus locally planned spares. Cooling water, extra pilots, working fills and service capacity are not calculated.
| Item / issue specification | Per equipped set | Class provision (11 sets) |
|---|---|---|
| 1 | 11 | |
| 1 kit | 11 kits | |
| 1 condenser 2 hoses |
11 condensers 22 hoses |
|
| 1 | 11 | |
| 1 support kit | 11 kits | |
| 1 heating kit | 11 kits | |
| 1 of each | 11 of each | |
| 1 | 11 | |
| 1 issue kit | 11 kits | |
| 125 mL | 1,375 mL | |
| 2 portions | 22 portions + local spares |
|
| Per person | Count people separately |
Book the solution batch, cold granule portions, spare compatible glassware, spill/first-aid provision and a protected cooling area. Prepare labels before the practical.
Confirm coolant supply/drainage and electrical loading at the actual bench. Allow setup, full cooling and reset time. Use fewer supervised stations where services or staffing limit safe operation.
Check glassware → separate the two flow paths → test coolant → pilot the safe finish

Confirm a known aqueous NaCl batch and the approved 50 mL charge. Inspect the flask, condenser and adapters. Add the specified fresh granules while cold; staff assemble delicate thermometer fittings.
Match joint sizes and clamp locations to the actual set. Route coolant hoses without pulling the glass. Trace the inner vapour path separately from the outer water jacket. Keep electrical leads dry.
Check coolant flow, gentle boiling, readable head temperature, droplet collection and a safe 10 mL stop. Allow for residual heat and delayed drips. Record any earlier stop limit and the cooling procedure.
| Part | Required position / check | Avoid |
|---|---|---|
| Boiling flask | 50 mL in the 100 mL flask; securely supported. | Overfilling or a hot refill. |
| Thermometer sensor | At the side-arm entrance, in the vapour stream. | Measuring the liquid or cooling jacket instead. |
| Condenser | Slope down towards the receiver; support the body. | Uphill collection or strained joints. |
| Cooling jacket | Lower inlet, upper outlet; flow checked while cold. | Reversed hoses or a loose drain end. |
| Receiver and outlet | Open cylinder; tip above the rising liquid level. | Sealed neck or a submerged delivery tip. |
| Heat source | Accessible control and approved heat-removal arrangement. | Moving unsupported hot glassware. |
Water changes from liquid to vapour and back to liquid. Dissolved sodium chloride is non-volatile under these conditions and is expected to remain in the flask. Splash carry-over can contaminate the receiver. [6]
Read the head temperature during active collection. For water it is usually near 100 °C at ordinary atmospheric pressure, but placement, heat loss and pressure affect the reading. Do not treat a single value as proof of purity. [4]
| Run / starting charge | Head temperature / °C | Distillate collected / mL | Appearance / stop reason / issue |
|---|---|---|---|
| ________ | ________ | ________ | |
| ________ | ________ | ________ |
Check cooling, glassware and heating first · retain observations · cool before touching
| Problem | What to check | Technician action |
|---|---|---|
| No distillate appears | Heat setting, coolant connections, leaks and the condenser slope. | Do not turn the heater straight to maximum. Staff check the pilot and cold setup before a fresh run; stop for vapour escaping outside the apparatus. |
| Violent boiling / droplets carry over | Heating rate, fill volume, granules and contamination. | Stop heating if safe and alert staff. Do not add granules to the hot liquid. Mark the collected sample as potentially contaminated. |
| Coolant stops or a hose leaks | Supply, drain security, kinks and wet electrical parts. | Stop heating if safe; alert staff and keep clear of wet electrics. Do not restore cold flow suddenly to an overheated condenser; staff assess before restart. |
| Unexpected temperature reading | Sensor position, instrument range and whether collection has started. | Record the actual reading. Adjust only once cooled, as approved; do not force the display to 100 °C by overheating. |
| Receiver fills / liquid approaches tip | Collection target, receiver position and delayed drips. | Stop at the approved limit while liquid remains in the boiling flask. Keep the gas path open; staff manage any receiver change safely. |
| Residue level becomes low / suspect blockage | Over-running, wrong charge, obstruction or an overheated flask. | Stop heating if safe, stand clear and alert staff. Do not top up, force joints or attempt to clear an active hot system. |
Reference check: 14 October 2026. AQA curriculum context [1] [2]; OCR apparatus principles [3]; Nichols and Flinn distillation technique [4] [6]; HSE assessment guidance [5]. Full references and scope limits appear below the printable charts.
The salt concentration, charge, collection target and calculator are editorial planning choices, not a laboratory-validated or endorsed school protocol. Use the actual equipment instructions and local approval.


Explore buying guides, practical resources and laboratory reference information.
This Technician Practical Essentials guide brings together the issue list, cold assembly checks, heating and cooling sequence, observations and clear-down for a simple-distillation station. It complements our Curriculum Experiments resources.
Source basis and adaptation: the layout and calculator pattern follow the preceding guides. AQA provides the GCSE water-practical context; OCR, Flinn and Lisa Nichols describe general distillation equipment or technique. [1] [2] [3] [4] [6] The 1% m/v sodium chloride solution, 50 mL charge, 100 mL round-bottom flask, 25 mL receiver and 10 mL collection target are this guide’s worked planning choices. They are not a verbatim examination-board method, a validated classroom recipe or a substitute for the actual apparatus instructions.
AQA Chemistry required practical 8 and Trilogy activity 13 include pH, dissolved-solids work and distillation on water samples. C19 develops only the distillation technique. It overlaps C08’s water work but does not by itself complete the wider practical. [1] [2]
One run begins with a fresh 50 mL charge in cooled apparatus and ends with a supervised stop and full reset. A second temperature reading or another drop of distillate is not a new run. Do not use repeated hot top-ups to avoid cooling.
Use an identified sodium chloride solution, not seawater, scented water or an unknown sample. The 1% m/v example means 1 g NaCl in 100 mL final solution, equivalent to 10 g/L. Staff specify the compatible anti-bumping material and portion; the calculator counts fresh portions without inventing a granule mass.
Check the entire kit together, including joint sizes, thermometer sensing length, condenser fittings, mantle/controller and supports. A catalogue search does not establish compatibility. Establish how many complete stations the available coolant supplies, drains, electrical circuits and staff can support.
Document an initial cold leak/flow check and a supervised heated trial with the selected sample. Agree the collection target, any earlier stopping condition, safe heater lowering and residual-heat management. Record the time required for full cooling before another run; the calculator does not estimate lesson duration.
This issue records distillate appearance, head temperature and collected volume. It does not include ion tests, conductivity measurements, pH testing or evaporation-to-dryness analysis. Any extension needs its own controls, apparatus, reagents and waste plan. Never taste a sample to test for salt.
The condenser’s inner tube carries vapour and condensate; the jacket carries cooling water. OCR’s apparatus guidance specifies entry at the lower coolant port so the jacket fills. [3] For this station, the collecting cylinder is open and the delivery end remains clear of the liquid. Do not copy a gas-test arrangement in which the outlet dips into a liquid receiver.
The head thermometer is not an instruction to make the whole apparatus exactly 100 °C. Use its reading during active collection, with the sensor correctly positioned. The normal boiling point of water is a contextual expectation, not a required display value or a drinking-water test. [6] [7]
Fixed example: 10 working stations + 1 extra complete set, two complete cold-start runs per set and 25% solution allowance. The interactive calculator updates Chart 2; this worked example stays fixed.
10 + 1 = 11 equipped sets.
One boiling flask, condenser, thermometer, receiver and heating/support kit per set.
Two coolant hoses per set = 22 hoses.
Two runs do not require two copies of every item when the apparatus is safely cooled, cleaned and reused.
50 mL × 2 runs = 100 mL per set before allowance.
100 × 1.25 = 125 mL per set.
125 × 11 = 1,375 mL for the class.
2 runs × 11 sets = 22 fresh granule portions, with dose and additional spares set locally.
Rounding: solution supply is rounded up to whole millilitres for each set, then multiplied. For one run with 25% allowance, 62.5 mL becomes 63 mL per set. This avoids under-issuing separately dispensed supplies. The allowance does not increase the 50 mL flask charge or authorise additional collection.
Not included: cooling-water use and recirculator fills, cleaning water, extra pilots, unplanned repeats, reserve glassware, stock-preparation losses, electrical loading, supervision and cooling time. Check these separately before deciding the number of simultaneous stations. An extra complete set already includes the same run allowance as each working set.
This guide restricts the sample to a known aqueous salt solution and uses a controlled electric mantle. It does not authorise alcohol distillation, vacuum work, improvised heaters or heating unknown mixtures. Evaluate hot surfaces, steam, breakage, hose security, water near electrical parts and accessible isolation alongside the actual substance information. HSE distinguishes safety-data-sheet information from the risk assessment itself. [5]
Keep the apparatus supported while cooling. Staff determine when heat input has ceased, coolant can be shut off and joints can be handled. Identify the remaining solution, samples, granules and rinsings for the approved local routes; changing the solute changes the waste decision. Do not generalise an external source’s disposal instructions to every school setup.
Checked 14 October 2026. References support the stated principles; the preparation quantities and local release checks above are editorial choices.
The public AQA and HSE pages, OCR guide, Flinn sheet and Nichols technique text were consulted. No member-only CLEAPSS method, product-specific SDS or instructions for the school’s exact distillation set were reviewed. Before issue, trained staff must check current authorised guidance and the actual equipment, then approve and pilot the complete activity. No source organisation has approved this guide.
Have feedback or a useful technician tip? Please contact us.
Draft prepared: 14 October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.
Build the issue around a compatible distillation set, independently supported glassware, controlled heating and dependable cooling. Confirm the local method, glass joint sizes, flask capacity and heater compatibility before ordering. This is not a pre-approved kit.
Links open in a new tab or window. These are catalogue searches, not verified product matches or availability claims. Confirm material suitability, joint sizes, connections, heater controls and current stock. Solution preparation and service checks are separate staff procedures.