We use cookies to give you the best experience possible. By continuing to use the site, you indicate that you accept cookies. See our cookies policy here.
Better Equipped Technician Practical Essentials
A quick-reference, six-page guide for technicians preparing a GCSE paper chromatography investigation: what to issue, how to pilot the samples, how to keep spots above the solvent, what to measure and how to clear down. For more detailed curriculum practical resources, visit our Curriculum Experiments resources.

One paper carries all five samples · water solvent · no external heating
One reusable chamber per set · five samples share one paper · fresh consumables for repeats
One complete run develops A–D and U together on one paper. Extra complete sets include the selected run plan. Consumable spares add whole paper-and-five-spotter sets, rounded once for the class. Solvent water is rounded up to 10 mL per equipped set, then multiplied by sets. Enter the actual chamber charge established in the pilot: input limits are not approved fill limits.
EACH sample is a prepared issue allowance for the whole set, not a dose to spot or a per-run quantity. It must cover all selected runs; increase it if the pilot needs more. Water for cleaning and stock preparation is extra. Spare paper does not automatically book additional full runs or solvent. This is not a dye-mixing recipe. Settings and ticks are not saved.
Planning issue: 10 stations + 1 extra set = 11 equipped sets. Two complete chromatograms per set give 22 planned runs. With 20% consumable spares, prepare 27 paper rectangles and 135 spotting capillaries (five per paper). At 10 mL water per run plus 20% allowance, prepare 30 mL solvent water per set: 330 mL for the class. Issue 1 mL of EACH of A, B, C, D and U per set: 11 mL of EACH sample in 55 labelled vials.
| Item / issue specification | Per equipped set | Class provision |
|---|---|---|
| 1 | 11 | |
| 1 assembly | 11 assemblies | |
| 2 + class spares | 27 papers | |
| 5 per paper | 135 tubes | |
| 5 vials + 1 rack | 55 vials + 11 racks | |
| 1 mL EACH | 11 mL EACH | |
| 30 mL / set | 330 mL | |
| 1 of each | 11 of each | |
| 1 of each | 11 of each | |
| 1 of each | 11 of each | |
| 2 + class spares | 27 records | |
| Per person | Count people separately |
Scissors for staff pre-cutting; labelled sample stocks and U preparation record; sample transfer tools; drying space and a clock. Add cleaning water, spill/first-aid provision, handwashing and a suitable glass-sharps container.
Only tiny spots go on the paper. One vial issue serves a complete set’s planned runs. Reuse the chamber after cleaning; do not multiply reusable kit by five lanes or by the number of separated spots.
Select compatible dyes → pilot the paper and water → organise lanes → preserve the solvent front

Select water-compatible references A–D; prefer verified single dyes. For the worked U, combine two references and a third dye not issued as A–D. Keep the actual recipe and identities in the staff record; pilot before issue. [3]
Use the actual paper, sample batches, spotting tools and chamber. Confirm small spots remain distinct and the front travels far enough to measure. Establish water charge, stop position and development/drying time; do not promise a fixed duration. [3] [5]
Pre-cut paper to hang flat without wall contact. Check suspension, cover fit and the bottom-edge depth. Label vials and spotters separately. Keep the completed pilot as a teacher reference, not a replacement for pupil evidence.
| Feature | Position / check |
|---|---|
| Initial water surface | A shallow layer, no more than 1 cm deep; below all sample spots. |
| Pencil baseline | 2 cm above the paper’s lower edge; every sample starts on this line. |
| Final solvent front | The wet leading edge when the paper is removed; mark it immediately, before drying. |
Paper bottom in water; spots dry and above the liquid; five lanes identified; no creases or wall contact. Keep the support secure and the chamber level. Use the same paper, water, cover arrangement and room conditions for comparisons.
Keep pencil, forceps and drying space ready before removal. Mark each paper’s own front. If the front is lost or runs off the top, flag the run; do not estimate it from a reference strip. Label run ID, samples and actual times.
| Lane / spot ID | Colour / appearance | Spot distance d / mm | Front distance s / mm | Rf / possible match |
|---|---|---|---|---|
| A–D / ____ | ||||
| U / spot 1 | ||||
| U / spot 2 | ||||
| U / further spot |
Check the setup before changing the solvent · record unresolved spots honestly
| Problem | What to check | Technician action |
|---|---|---|
| Samples wash into the water | Baseline submerged; too much water; paper slipped in its support. | Stop and retain the failed record. Clean the chamber, reset the depth and start with a new spotted paper. |
| Large smears or overlapping spots | Oversized or still-wet starting spots; concentrated sample; lanes too close. | Practise tiny applications and drying between touches. Pilot any dilution first, label it and rerun consistently. |
| Little movement or no separation | Sample–water compatibility, dye formulation, paper batch and elapsed time. | Compare with the pilot. Do not add alcohol or change paper mid-run. An immobile spot is an observation, not proof of purity. |
| Sloping or curved solvent front | Wall contact, a crease, slanted paper, uneven immersion or a disturbed chamber. | Flag the geometry problem. Correct the support for a new run; do not draw an invented straight front through the result. |
| Front is missing or off the top | Late removal or failure to mark the wet edge before drying. | Do not calculate a reliable Rf without a measurable front. Keep the observation and repeat; never borrow another paper’s distance. |
| Unexpected extra spots / poor agreement | Mixed-up labels, shared capillaries, dirty glassware, different paper or changed sample stock. | Check against sample-specific spotters and the pilot. Keep raw evidence and repeat under the same conditions; do not delete an unmatched spot. |
Reference check: 11 October 2026. AQA curriculum and handbook [1] [2] [3] [4]; RSC technique guidance [5]. Full sources, access limits and adaptations are online. The supply allowances, complete-run planning and detailed release checks are editorial choices requiring a local pilot and approval. No examination-board, RSC or CLEAPSS endorsement is claimed.


Explore buying guides, practical resources and laboratory reference information.
This Technician Practical Essentials guide brings together sample preparation, class quantities, chamber setup, observation, Rf calculations and clear-down for GCSE paper chromatography. It complements our Curriculum Experiments resources.
Source basis and adaptation: AQA provides the curriculum context and a food-dye practical with references A–D and unknown U. [1] [2] [3] The water charge, sample issue volumes, spare-paper allowance, two-run default, air-drying choice and extended troubleshooting are editorial preparation choices. The five-lane plan is not five independent repeats. This guide has not been laboratory-validated and requires local review and a pilot.
AQA Chemistry practical 6 and Trilogy practical 12 both include separation of coloured substances and calculation of Rf. [1] [2] The teacher should plan pupils’ own measurements and records, not just display a prepared chromatogram. Other courses and any wider investigations must be checked against their specifications.
Record the actual dye ingredients and batches. A bottle labelled with one colour may contain more than one dye. The handbook favours single-dye references and suggests an unknown with two known dyes plus a third not in A–D. [3] Keep the additional dye identity in the staff key; an unmatched spot should remain unmatched in the pupil conclusion.
Trial the exact paper, water and sample combination, including U, not just one attractive ink. Confirm separation and a practical stop position before the front reaches the paper top. Changing solvent or paper changes the comparison. RSC also stresses trialling sample choice; its ink example is not the same five-food-dye design. [5]
The 250 mL chamber is a starting specification, not a guarantee that a particular strip fits. Size paper to give room for all five lanes without wall contact. A loose cover is included here for consistency; AQA notes it is not essential with water. [3] Use clean, supplier-specified chromatography spotters; capacity and safe handling matter more than a generic “capillary” label. [6]
Chromatography separates substances through their different distributions between a stationary phase and a mobile phase; here the water moves through the paper system. Rf compares the spot’s displacement with the solvent front’s displacement from the same origin. It is not a speed, a concentration or a percentage yield. [4] An unmoved visible spot can have Rf = 0; absence of a measurable spot is not a zero-distance measurement.
Use like-for-like conditions and a reference on the same paper where possible. Record colour, spot shape and confidence in the centre as well as the ratio. A match is evidence consistent with a shared component, not proof of chemical identity. Two components may overlap, and a colourless component may not be visible. Do not add an unassessed locating reagent to make it visible.
For one measured lane, let the solvent front be 60 mm above the baseline. Two distinct spot centres are 24 mm and 42 mm above it. Their Rf values are 24 ÷ 60 = 0.40 and 42 ÷ 60 = 0.70. Both distances in each ratio use the same unit, so the ratio has no unit. These invented numbers explain the calculation only; they do not identify a named dye.
For a repeat with a different front distance, calculate that paper’s ratios first. If a corresponding spot travels 26 mm with a 65 mm front, its Rf is again 0.40. Compare the paired ratios rather than treating different solvent distances as interchangeable. Average only measurements of the same resolved component under comparable conditions, with the teacher’s agreed rounding and exclusions.
Equipped sets = working stations + extra complete sets. Each reusable set runs one paper at a time. Planned papers = sets × complete chromatograms per set. Add the chosen percentage of spare paper-and-spotter sets, rounded up once for the class; each extra paper gets five extra capillaries. Sample vials remain five per equipped set, not five per spot observed.
Solvent water per set is the pilot charge × planned runs × handling allowance, rounded up to the next 10 mL. Class solvent is that amount × sets. This is issue stock, not a depth instruction. Spare papers do not automatically schedule extra full runs: raise the run count when those runs are intended. Cleaning water and sample preparation are additional.
Each prepared sample has a separate per-set issue allowance multiplied by the number of sets. It covers all chosen runs and should be confirmed in the pilot. The calculator does not calculate U’s mixing proportions or the additional source dyes consumed to prepare it. Keep those stock-preparation quantities in the technician’s separate record.
Checked 11 October 2026. Curriculum pages were read directly. The AQA handbook text was consulted, with its student method, setup drawing and results table also inspected as page images. RSC’s publicly indexed procedure and technical notes were available, but direct page access failed; no linked RSC downloads were reviewed.
Consult current relevant CLEAPSS guidance through your school’s access alongside employer instructions and the actual supplier information. Member-only CLEAPSS guidance was not consulted. A water solvent does not remove the need to assess the dyes, glass capillaries, eye protection and waste route. No supplier or examination-board approval is implied.
Have feedback or a useful technician tip? Please contact us.
Draft prepared: October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.
Build the issue around consistent chromatography paper, stable chambers, clean spotting tools and clearly labelled water-based samples. Use the apparatus checklist and pilot to confirm dimensions, compatibility and quantities. These catalogue searches are not a pre-approved kit.
Check that the paper is suitable for the chosen separation. Confirm capillaries are appropriate for spotting, not simply a similarly named tube; staff should not improvise glass modifications. Dye suitability must be tested with water.
Links open in a new tab or window. Catalogue searches do not guarantee a matching item or availability. Current product pages, packs and specifications were not verified; check them before ordering. Paper supports, loose covers and a labelled drying area must also be arranged.