Login

Skip to the practical guide

Better Equipped Technician Practical Essentials

Separating mixtures by paper chromatography

Water-based food dyes · reference samples and an unknown · Rf values

A quick-reference, six-page guide for technicians preparing a GCSE paper chromatography investigation: what to issue, how to pilot the samples, how to keep spots above the solvent, what to measure and how to clear down. For more detailed curriculum practical resources, visit our Curriculum Experiments resources.

GCSE ChemistryPaper chromatographyC06 · Technician referencev1.0 October 2026
gcse chemistry separating mixtures

Print all six pages on A4 portrait. Choose Save as PDF or your printer in the print window. Use 100% scale and turn off browser headers and footers.

To print, use your browser’s Print command: Ctrl+P (Windows) or Cmd+P (Mac).

Scope: ascending paper chromatography of water-soluble food-dye preparations, with four labelled references A–D and an unknown U run alongside them. This supports AQA Chemistry required practical 6 and Combined Science: Trilogy practical 12, including calculation of Rf values. [1] [2] C06 is our guide code; check other specifications separately. Organic solvents, plant-pigment extraction and thin-layer chromatography need separate methods and assessments.
Five sample lanesA, B, C, D and U on one paper
Use pencilBaseline, sample labels and solvent front
Keep spots dry at the startBaseline above the water surface
Mark before dryingRecord the wet solvent front immediately
Measure from the baselineTo spot centre and solvent front
Better EquippedTechnician Practical EssentialsC06 · GCSE Chemistry

Paper chromatography

The practical at a glance

One paper carries all five samples · water solvent · no external heating

Paper Chromotography Methodology
5 sample lanesfour references + one unknown
2 cm baselineabove a shallow water layer
Rf = d ÷ ssame units; ratio has no units
Question: which separated coloured components in U are consistent with the reference samples? Compare both spot colour and Rf under the same conditions. Keep unmatched spots in the record. [3] [4]
  1. Check the samplesUse the labelled A–D and U preparations and the piloted paper–water combination. Record sample IDs and paper type. Do not replace a stock or solvent part-way through the comparison.
  2. Mark the paperHandle the edges. Draw a light pencil baseline 2 cm from the lower edge. Mark five spaced positions, A–D and U, at least 5 mm from the paper edges. Check the strip fits without touching the chamber walls. [3]
  3. Apply small, dry spotsUse a separate spotting capillary for each sample; aim for 2–3 mm spots. Allow spots to dry. If a second touch is needed, place it on the same dry spot rather than enlarging it. Do not puncture the paper. [3] [5]
  4. Start the separationAdd the pilot-confirmed shallow water charge, no more than 1 cm deep. Suspend the paper vertically with its bottom in water but its baseline and spots above the surface. Fit the agreed loose cover without shifting the support. [3]
  5. Watch and mark the frontLeave the chamber level and undisturbed. Remove the paper at the agreed front position, before the solvent reaches the top. Mark the wet solvent front immediately in pencil, then air-dry the labelled paper. [3]
  6. Measure and calculateFrom the baseline, measure to each resolved spot’s centre (d) and to the marked solvent front (s) along that lane. Calculate Rf = d / s using the same units. Record every visible spot, including all spots in U. [4]
  7. Compare and repeatCompare U with the references on the same chromatogram. For a complete repeat, use fresh paper, fresh water and clean sample-specific spotters. Calculate each run’s ratios separately; preserve failed or unclear separations rather than inventing distances.
Illustrative calculation: a spot centre 24 mm above the baseline with a solvent front 60 mm above it gives Rf = 24 ÷ 60 = 0.40. This is not an expected value for a particular dye. Never measure from the bottom edge of the paper.
Before issue: approve the method and risk assessment; check the actual dye formulations and supplier information. Wear the specified eye protection. Do not taste food dyes or mouth-fill capillaries. Collect glass spotters through the approved sharps route. This example uses water only: no flames, heaters or organic solvents.
Better EquippedTechnician Practical EssentialsC06 · GCSE Chemistry

Apparatus and materials

One reusable chamber per set · five samples share one paper · fresh consumables for repeats

 
Interactive calculator not active. Fixed example: 10 stations + 1 extra set; two chromatograms per set; 10 mL solvent water per run; 20% solvent allowance and 20% consumable spares. Prepare 11 sets, 27 papers, 135 capillaries, 330 mL solvent water and 11 mL of EACH prepared sample A–D and U. Adjust locally when scripting is unavailable.

Planning issue: 10 stations + 1 extra set = 11 equipped sets. Two complete chromatograms per set give 22 planned runs. With 20% consumable spares, prepare 27 paper rectangles and 135 spotting capillaries (five per paper). At 10 mL water per run plus 20% allowance, prepare 30 mL solvent water per set: 330 mL for the class. Issue 1 mL of EACH of A, B, C, D and U per set: 11 mL of EACH sample in 55 labelled vials.

Item / issue specification Per equipped set Class provision
1 11
1 assembly 11 assemblies
2 + class spares 27 papers
5 per paper 135 tubes
5 vials + 1 rack 55 vials + 11 racks
1 mL EACH 11 mL EACH
30 mL / set 330 mL
1 of each 11 of each
1 of each 11 of each
1 of each 11 of each
2 + class spares 27 records
Per person Count people separately

Shared preparation

Scissors for staff pre-cutting; labelled sample stocks and U preparation record; sample transfer tools; drying space and a clock. Add cleaning water, spill/first-aid provision, handwashing and a suitable glass-sharps container.

Check supply versus use

Only tiny spots go on the paper. One vial issue serves a complete set’s planned runs. Reuse the chamber after cleaning; do not multiply reusable kit by five lanes or by the number of separated spots.

Depth overrides volume. The example 10 mL is a planning entry, not a universal beaker fill. Check the actual water surface stays below the 2 cm baseline and the paper bottom remains immersed. Book additional solvent and samples for any extra full runs.
Better EquippedTechnician Practical EssentialsC06 · GCSE Chemistry

Preparation and apparatus set-up

Select compatible dyes → pilot the paper and water → organise lanes → preserve the solvent front

Paper Chromotography Set Up

1 · Prepare the sample set

Select water-compatible references A–D; prefer verified single dyes. For the worked U, combine two references and a third dye not issued as A–D. Keep the actual recipe and identities in the staff record; pilot before issue. [3]

2 · Run a complete pilot

Use the actual paper, sample batches, spotting tools and chamber. Confirm small spots remain distinct and the front travels far enough to measure. Establish water charge, stop position and development/drying time; do not promise a fixed duration. [3] [5]

3 · Cut, check and release

Pre-cut paper to hang flat without wall contact. Check suspension, cover fit and the bottom-edge depth. Label vials and spotters separately. Keep the completed pilot as a teacher reference, not a replacement for pupil evidence.

Three positions that must not be confused
Feature Position / check
Initial water surface A shallow layer, no more than 1 cm deep; below all sample spots.
Pencil baseline 2 cm above the paper’s lower edge; every sample starts on this line.
Final solvent front The wet leading edge when the paper is removed; mark it immediately, before drying.

Ready-to-run check

Paper bottom in water; spots dry and above the liquid; five lanes identified; no creases or wall contact. Keep the support secure and the chamber level. Use the same paper, water, cover arrangement and room conditions for comparisons.

Preserve the evidence

Keep pencil, forceps and drying space ready before removal. Mark each paper’s own front. If the front is lost or runs off the top, flag the run; do not estimate it from a reference strip. Label run ID, samples and actual times.

One record per chromatogram — add a row for EVERY resolved spot
Lane / spot ID Colour / appearance Spot distance d / mm Front distance s / mm Rf / possible match
A–D / ____        
U / spot 1        
U / spot 2        
U / further spot        
Use one origin: measure both distances from the pencil baseline, along the direction of solvent travel. For a slightly uneven front, use the marked front for that lane and record the limitation. A severely distorted or overlapping result needs a fresh run, not a guessed spot centre.
Paper / batch: Water / run: mLStop position / timing: Pilot checked:
Better EquippedTechnician Practical EssentialsC06 · GCSE Chemistry

Troubleshooting and clear-down

Check the setup before changing the solvent · record unresolved spots honestly

Problem What to check Technician action
Samples wash into the water Baseline submerged; too much water; paper slipped in its support. Stop and retain the failed record. Clean the chamber, reset the depth and start with a new spotted paper.
Large smears or overlapping spots Oversized or still-wet starting spots; concentrated sample; lanes too close. Practise tiny applications and drying between touches. Pilot any dilution first, label it and rerun consistently.
Little movement or no separation Sample–water compatibility, dye formulation, paper batch and elapsed time. Compare with the pilot. Do not add alcohol or change paper mid-run. An immobile spot is an observation, not proof of purity.
Sloping or curved solvent front Wall contact, a crease, slanted paper, uneven immersion or a disturbed chamber. Flag the geometry problem. Correct the support for a new run; do not draw an invented straight front through the result.
Front is missing or off the top Late removal or failure to mark the wet edge before drying. Do not calculate a reliable Rf without a measurable front. Keep the observation and repeat; never borrow another paper’s distance.
Unexpected extra spots / poor agreement Mixed-up labels, shared capillaries, dirty glassware, different paper or changed sample stock. Check against sample-specific spotters and the pilot. Keep raw evidence and repeat under the same conditions; do not delete an unmatched spot.
Matching supports identification; it does not prove it. Compare colour and Rf with known references run under the same conditions. Different substances can travel together; one visible spot is consistent with a single detected component, not a universal purity certificate. [4]
Water-only scope: some dyes or inks will not give useful separation in water. Review sample choice before the lesson. Ethanol, propanone, plant extracts and locating reagents need their own approved method, formulation checks, ventilation, ignition controls and waste arrangements. They are not automatic substitutions. [5]

Clear-down and reset

01 · Keep the recordRetain labelled dry papers, distances, ratios and repeat comparisons. Record unmatched, merged or unmeasurable spots. Do not turn a missing reading into zero.
02 · Separate the wasteCollect glass spotters in the approved sharps container, not loose in bins or sinks. Dispose of dye solutions and rinsings by the assessed route for the actual formulation; keep spare stocks separate.
03 · Clean and storeClean chambers, supports and trays; dry before reuse. Cap labelled samples and follow supplier storage guidance. Remove staining and spills as directed; wash hands. Nothing from the activity is for consumption.
Prepared by: School method / RA: Waste route:

Reference check: 11 October 2026. AQA curriculum and handbook [1] [2] [3] [4]; RSC technique guidance [5]. Full sources, access limits and adaptations are online. The supply allowances, complete-run planning and detailed release checks are editorial choices requiring a local pilot and approval. No examination-board, RSC or CLEAPSS endorsement is claimed.

Better EquippedTechnician Practical EssentialsC06 · GCSE Chemistry

Paper chromatography · Methodology infographic

Paper Chromotography Methodology
Better EquippedTechnician Practical EssentialsC06 · GCSE Chemistry

Paper chromatography · Apparatus set-up infographic

Paper Chromotography Set Up
More practical support from Better Equipped

Explore buying guides, practical resources and laboratory reference information.

Visit Better Resources →

About this guide

This Technician Practical Essentials guide brings together sample preparation, class quantities, chamber setup, observation, Rf calculations and clear-down for GCSE paper chromatography. It complements our Curriculum Experiments resources.

Source basis and adaptation: AQA provides the curriculum context and a food-dye practical with references A–D and unknown U. [1] [2] [3] The water charge, sample issue volumes, spare-paper allowance, two-run default, air-drying choice and extended troubleshooting are editorial preparation choices. The five-lane plan is not five independent repeats. This guide has not been laboratory-validated and requires local review and a pilot.

Curriculum and investigation

AQA Chemistry practical 6 and Trilogy practical 12 both include separation of coloured substances and calculation of Rf. [1] [2] The teacher should plan pupils’ own measurements and records, not just display a prepared chromatogram. Other courses and any wider investigations must be checked against their specifications.

Selecting the sample set

Record the actual dye ingredients and batches. A bottle labelled with one colour may contain more than one dye. The handbook favours single-dye references and suggests an unknown with two known dyes plus a third not in A–D. [3] Keep the additional dye identity in the staff key; an unmatched spot should remain unmatched in the pupil conclusion.

Pilot the whole system

Trial the exact paper, water and sample combination, including U, not just one attractive ink. Confirm separation and a practical stop position before the front reaches the paper top. Changing solvent or paper changes the comparison. RSC also stresses trialling sample choice; its ink example is not the same five-food-dye design. [5]

Chamber and spotting choices

The 250 mL chamber is a starting specification, not a guarantee that a particular strip fits. Size paper to give room for all five lanes without wall contact. A loose cover is included here for consistency; AQA notes it is not essential with water. [3] Use clean, supplier-specified chromatography spotters; capacity and safe handling matter more than a generic “capillary” label. [6]

Interpreting the chromatogram

Chromatography separates substances through their different distributions between a stationary phase and a mobile phase; here the water moves through the paper system. Rf compares the spot’s displacement with the solvent front’s displacement from the same origin. It is not a speed, a concentration or a percentage yield. [4] An unmoved visible spot can have Rf = 0; absence of a measurable spot is not a zero-distance measurement.

Use like-for-like conditions and a reference on the same paper where possible. Record colour, spot shape and confidence in the centre as well as the ratio. A match is evidence consistent with a shared component, not proof of chemical identity. Two components may overlap, and a colourless component may not be visible. Do not add an unassessed locating reagent to make it visible.

Worked Rf example — illustrative data, not expected results

For one measured lane, let the solvent front be 60 mm above the baseline. Two distinct spot centres are 24 mm and 42 mm above it. Their Rf values are 24 ÷ 60 = 0.40 and 42 ÷ 60 = 0.70. Both distances in each ratio use the same unit, so the ratio has no unit. These invented numbers explain the calculation only; they do not identify a named dye.

For a repeat with a different front distance, calculate that paper’s ratios first. If a corresponding spot travels 26 mm with a 65 mm front, its Rf is again 0.40. Compare the paired ratios rather than treating different solvent distances as interchangeable. Average only measurements of the same resolved component under comparable conditions, with the teacher’s agreed rounding and exclusions.

What the preparation calculator counts

Equipped sets = working stations + extra complete sets. Each reusable set runs one paper at a time. Planned papers = sets × complete chromatograms per set. Add the chosen percentage of spare paper-and-spotter sets, rounded up once for the class; each extra paper gets five extra capillaries. Sample vials remain five per equipped set, not five per spot observed.

Solvent water per set is the pilot charge × planned runs × handling allowance, rounded up to the next 10 mL. Class solvent is that amount × sets. This is issue stock, not a depth instruction. Spare papers do not automatically schedule extra full runs: raise the run count when those runs are intended. Cleaning water and sample preparation are additional.

Each prepared sample has a separate per-set issue allowance multiplied by the number of sets. It covers all chosen runs and should be confirmed in the pilot. The calculator does not calculate U’s mixing proportions or the additional source dyes consumed to prepare it. Keep those stock-preparation quantities in the technician’s separate record.

Have feedback or a useful technician tip? Please contact us.

Draft prepared: October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.

Everything you need for this practical

Build the issue around consistent chromatography paper, stable chambers, clean spotting tools and clearly labelled water-based samples. Use the apparatus checklist and pilot to confirm dimensions, compatibility and quantities. These catalogue searches are not a pre-approved kit.

Separation and sample preparation — catalogue searches

Check that the paper is suitable for the chosen separation. Confirm capillaries are appropriate for spotting, not simply a similarly named tube; staff should not improvise glass modifications. Dye suitability must be tested with water.

Measuring, handling and general laboratory supplies