Login

Skip to the practical guide

Better Equipped Technician Practical Essentials

Culturing microorganisms and aseptic technique

Approved teaching cultures on nutrient agar

A quick-reference, six-page guide for technicians preparing a GCSE microbiology practical: what to issue, how to organise aseptic transfer, how to manage incubation and closed-plate observations, and how to arrange clear-down. For more detailed curriculum practical resources, visit our Curriculum Experiments resources.

GCSE BiologySupporting practicalB19 · Technician referencev1.0 October 2026
gcse biology Culturing microorganisms and aseptic technique

Print all six pages: the four text charts followed by the two infographic pages. Use A4 portrait. Choose Save as PDF or your printer in the print window. Use 100% scale and turn off browser headers and footers.

To print, use your browser’s Print command: Ctrl+P (Windows) or Cmd+P (Mac).

Scope: a supporting aseptic-technique activity using a known, school-approved teaching strain, prepared nutrient agar plates and an unopened medium control. It supports AQA GCSE Biology 8461 section 4.1.1.6 (Biology only), but is not a replacement for required practical 2, which investigates antiseptics or antibiotics and zones of inhibition. [1] B19 is our guide code. Environmental sampling, finger dabs, clinical material, microbial identification, antimicrobial testing and genetic modification are outside this example.
CultureKnown teaching strain · staff approved
MediumSterile, prepared nutrient agar plates
ControlUninoculated plate · kept unopened
IncubationInverted · monitored · maximum 25°C
After growthObserve closed · staff decontamination
Better EquippedTechnician Practical EssentialsB19 · GCSE aseptic technique

Culturing microorganisms and aseptic technique

The practical at a glance

Known teaching culture · aseptic handling · a medium control · closed-plate observation

Culturing microorganisms and aseptic technique methodology
1 + 1 platesone inoculated plate and one unopened control per set
Maximum 25°Cuse the agreed, monitored school incubation conditions
Two lesson stagesset up first; observe later without removing lids
Aim: practise transferring an approved culture without introducing unwanted microorganisms or spreading the culture outside its container. Record visible growth on the inoculated plate and compare it with the unopened medium control. This is a technique exercise, not a hygiene survey or a test of microbial identity.
  1. Check and briefConfirm the teacher-approved strain, method and disposal arrangements. Use only the issued culture; do not substitute samples from hands, surfaces, food or the environment. Rehearse handling with empty apparatus first.
  2. Prepare and labelDisinfect the work area using the selected product and contact time. Label the agar-containing base of each dish at its edge: class/station, date, culture or “uninoculated control”. Keep the control closed. [3] [5]
  3. Transfer asepticallyFollow the demonstrated school transfer method. Lift the inoculation plate lid only enough for access, protect sterile contact surfaces, and use a sterile loop to apply the agreed surface pattern without gouging the agar. Close promptly; place used disposable loops in the designated discard container. [3] [5]
  4. Secure the lidsApply short strips of tape at opposite edges, as specified by the school method. Secure against accidental opening, but do not tape continuously around the rim. The control is secured too. [2] [4]
  5. Incubate under staff controlStaff log and place dishes base uppermost, lid underneath. Use agreed conditions within 20–25°C, never above 25°C for this guide. Book the review time in advance; monitor the actual temperature rather than relying only on a dial setting. [1] [4]
  6. Observe without openingAt the planned review, staff check plates before issue. Record visible growth, its distribution and the control result through the closed dish. Do not remove lids, sniff cultures or pick colonies. Use supplied images if viewing is unsuitable.
  7. Return and decontaminateAccount for every plate and return it closed for staff-managed sterilisation and disposal. Clean the workspace and wash hands. Do not put live cultures into sinks or ordinary waste, or take plates home. [2]
Control limitation: an unopened control checks for detectable growth in that medium under the same incubation/storage conditions. It does not test the pupil’s transfer procedure or prove that the inoculated plate contains only one organism.
Before issue: staff must have an approved culture, suitable training, a risk assessment, spill arrangements and a working decontamination route. If any are missing, use a non-culture demonstration or supplied images/data instead. [2] [3]
Better EquippedTechnician Practical EssentialsB19 · GCSE aseptic technique

Apparatus and materials

Tick-box issue checklist · each set is an inoculated plate plus an unopened control

 

Interactive calculator not active. Static example: 10 stations × 1 set, plus 2 extra sets. Prepare 24 agar plates and 24 sterile disposable loops, including one spare loop per set. Edit quantities locally when JavaScript is unavailable.

Planning issue: 10 stations × 1 set + 2 extra sets = 12 sets. Prepare 24 agar plates (12 inoculated + 12 unopened controls), 24 sterile disposable loops including spares, and 10 working trays.

Item / issue specification Per station Class provision
2 × 1 24 plates
Staff issue Plan source culture separately
2 × 1 24 incl. spares
1 10
1 marker + tape 10 markers; tape for 24 plates
1 or supervised shared point Plan before inoculation
As assessed Prepare for both lesson stages
Per user Count pupils + staff
1 × 1 12 records; aids as needed
Shared Book capacity and trained staff

Prepared plates, not just empty dishes

Order or prepare sterile nutrient agar plates. Empty Petri dishes and nutrient agar powder are separate preparation supplies, not a ready-to-use plate. Plain agar alone is not equivalent to a formulated nutrient medium. Follow the approved medium and supplier storage instructions.

What the calculator includes

Totals are individual items, not packs. There are 12 plates for each role and 24 loops including spares. It does not calculate inoculum volume, growth time, disinfectant dilution or steriliser loading. Unused spare plates remain stock unless issued.

Choose the loop route before issue: the displayed quantity plan uses sterile disposable loops for a simple transfer exercise. A reusable metal-loop method needs its own burner/heat-mat provision, training, sterilisation and cooling steps. AQA’s specification includes explaining flame sterilisation; do not treat a disposable-loop activity as demonstrating that step. [1] [3]
Better EquippedTechnician Practical EssentialsB19 · GCSE aseptic technique

Preparation and apparatus set-up

Approve the strain → prepare the stations → label the controls → book review and disposal

Culturing microorganisms and aseptic technique set up

1 · Approve the culture

Record the full supplied identity and strain, source and date. Match the strain and medium to current employer guidance. Prepare class material through trained staff procedures; a purchased culture can still become contaminated. [2]

2 · Inspect the plates

Keep plates closed while checking labels, medium, expiry/storage history, cracks, drying and visible contamination. Use sterile pre-poured plates or staff-prepared batches. Reject unsuitable plates; do not wipe or scrape their agar.

3 · Arrange clean and used kit

Place sterile supplies within reach, separate from the discard point. Rehearse lid and container handling before live work. Confirm disinfectant contact time and any flame-related controls in the selected method. [3]

Plan the two plate roles before the practical
Plate role Handling / useful observation Limit of the conclusion
Inoculated plate Apply only the issued teaching culture using the demonstrated method. Later record growth through the closed dish. Visible colonies or streak growth do not establish identity, purity or a viable-cell concentration.
Unopened medium control Do not lift the lid. Use the same medium batch and incubation conditions. Record growth / no visible growth. No visible growth supports the medium check only. It does not demonstrate successful aseptic transfer.

Incubation and observation booking

Use the 20–25°C range, maximum 25°C, specified for this school example. The Practical Biology reference describes observation after 2–3 days; confirm a suitable interval for the approved strain and local method rather than guaranteeing that timetable. Record the actual temperature and arrange staff checks. [1] [4]

What pupils should record

Record plate ID/role, medium batch, stated culture identity, preparation date/time, incubation conditions and review time. Describe growth location and appearance without opening. Photograph through the lid if useful; mark “not assessable” when the view is obscured.

Closed does not mean airtight: before incubation, secure the lid with the approved short tape strips, not a full seal. Incubate inverted, with the agar-containing base above the lid, to reduce condensation dripping onto the agar. Keep incubated dishes closed during viewing. [1] [2] [4]

Staff release check

Protect the distinction: this simple transfer exercise does not promise isolated colonies. A dilution-streak method has additional loop sterilisation/replacement stages and a different issue plan. Do not add colony picking, subculturing or staining of incubated pupil plates to B19. [5]
Approved strain: Review date: Responsible staff:
Better EquippedTechnician Practical EssentialsB19 · GCSE aseptic technique

Troubleshooting and clear-down

Check records without opening grown plates · account for cultures · sterilise before disposal

Problem What to check Technician action
Growth on the unopened control Plate batch, storage, accidental opening, damaged packaging or a label mix-up. Keep it closed and flag the comparison. Staff review the batch and records, then arrange sterilisation. Do not pick colonies to identify the contaminant.
No visible growth on the inoculated plate Identity and condition of the issued culture, medium, logged temperature/time and any handling error. Review the approved method with staff. Do not raise the temperature or extend incubation indefinitely to force growth; use a fresh approved run or supplied images.
Unexpected colours or fuzzy growth Possible contamination, mixed material, incorrect labels or prolonged holding. Do not reopen, sniff or subculture. Keep the dish closed, segregate under staff procedures and use the approved disposal route.
Condensation obscures the view Incubation orientation, temperature changes and plate condition before issue. View from a different angle or use a staff photograph. Do not lift the lid or wipe inside. Record that the observation is obscured.
Agar is gouged or growth merges Loop pressure, amount transferred and whether a simple streak was mistaken for dilution streaking. Record qualitative growth, not an invented colony count. Improve technique with a non-culture rehearsal before a new approved run.
Loose lid, cracked plate or culture spill Stop work; prevent access to the affected area and alert the teacher. Do not improvise a pupil clean-up or handle broken contaminated material. Trained staff follow the biological spill and exposure procedure. [2] [3]
Temperature is only one safeguard: ≤25°C is the limit used here, not proof that a culture is harmless. Selection, containment, aseptic practice, supervision and effective disposal are still essential. No live plate should leave staff-controlled arrangements. [1] [2]

Clear-down and reset

01 · Account and containCount returned plates against the issue record, including controls. Keep dishes closed and collect used tools in their designated containers. Staff manage transport and storage before decontamination.
02 · Sterilise, then disposeTrained staff use the school’s validated sterilisation process for the actual load. Do not rely on a bench wipe, an external disinfectant soak or changed autoclave tape as proof that plate contents are sterile. [2] [3]
03 · Clean and close the recordClean/disinfect work surfaces using the selected instructions. Wash hands, check equipment and record treatment/disposal and any incident. Release waste only through the approved route.
If sterilisation is unavailable: do not begin a culture practical. If a fault develops afterwards, retain cultures securely and seek employer/CLEAPSS advice on an approved alternative route. A bin liner, sink or classroom disinfectant wipe is not a substitute.
Plates returned: Treatment record: Checked by:

Preparation references checked 5 October 2026: AQA culturing content [1]; public CLEAPSS SSS001 [2]; Microbiology Society technique manual [3]; Practical Biology incubation and streak-plate references [4] [5]. Full references and the boundaries of this adaptation are in “About this guide”.

This is an editorial preparation aid, not a validated strain-specific protocol or a claim of CLEAPSS/awarding-organisation approval. Use current employer guidance and the local risk assessment.

Better EquippedTechnician Practical EssentialsB19 · GCSE aseptic technique
Culturing microorganisms and aseptic technique methodology
Better EquippedTechnician Practical EssentialsB19 · GCSE aseptic technique
Culturing microorganisms and aseptic technique set up
More practical support from Better Equipped

Explore buying guides, practical resources and laboratory reference information.

Visit Better Resources →

About this guide

This Technician Practical Essentials guide supports the organisation of a GCSE aseptic-technique activity using a known teaching culture and prepared agar plates. It brings together the class issue, staff checks, controls, later observation and disposal planning. It complements our Curriculum Experiments resources.

The four-chart layout follows the established series. The paired-plate arrangement, unopened control, simple transfer focus and quantity allowances are editorial planning choices, not a prescribed examination-board protocol. The actual strain, source material, transfer method, incubation period and decontamination process must be approved locally.

Curriculum context and B06 overlap

AQA section 4.1.1.6 covers culturing and aseptic technique in separate Biology. Required practical 2 adds an antimicrobial investigation and inhibition-zone measurements; those are not included in B19. This guide is intended as supporting preparation and technique practice, not a claim that the full required practical has been completed. [1]

Teaching strains, not unknown samples

The title is broad; the worked organisation is deliberately limited to an approved bacterial teaching strain on a suitable medium. It is not an instruction to culture material from people, animals, food or the environment. Other activities need their own assessment and method; the source safety sheet discusses a wider scope than this guide adopts. [2]

Sterile and aseptic are not synonyms

Sterilisation is a process intended to eliminate viable microorganisms, including spores; aseptic technique protects the material and surroundings from contamination during handling. A disinfected bench is not a sterile field. For purchases, check the manufacturer’s sterility claim: a product described only as “aseptic” is not automatically equivalent to one supplied sterile. [3]

Disposable and reusable loop routes

This quantity plan uses sterile disposable loops. Keep the contact end untouched and use a new sterile item when required; do not flame plastic. Where a school chooses reusable metal loops, teach and assess the specific flame-sterilisation and cooling method and provide the necessary apparatus. Pre-sterilised loops do not replace any required explanation of that technique. [1] [3]

Why the control stays unopened

Keeping the control closed deliberately checks the medium and shared incubation/storage history, not the operator’s transfer skill. An additional handled blank could address a different question, but would need a defined, approved procedure and extra kit. Do not ask pupils to demonstrate “bad technique” by deliberately contaminating plates.

What the observations can establish

Compare the recorded appearance and distribution of growth with the stated culture and control role. A colony may arise from a cell or a cluster; this simple transfer plan does not determine the original number of organisms. Growth that looks uniform is not a conclusive identity or purity test. No-growth and obscured-view records are also different outcomes. [3] [5]

Incubation and source differences: this guide uses the current AQA school maximum of 25°C. Some older general microbiology examples use other ranges; those are not adopted here. The 2–3-day observation window in the Practical Biology reference is context for planning, not a universal promise. The local method must set a review and disposal time. [1] [3] [4]

Have feedback or a useful technician tip? Please contact us.

Draft prepared: October 2026 · Version: 1.0 · Technical review: pending confirmation before publication.

Everything you need for this practical

Plan the issue around approved teaching cultures, sterile prepared nutrient agar plates, sterile transfer tools, clear labelling and a managed disposal route. The links below include individual products and clearly labelled catalogue searches. Select to the school’s method; this is not a pre-approved kit.

Transfer and plate-preparation supplies — product links

Check what is supplied: the Petri dish link is for empty dishes; nutrient agar powder requires staff preparation and sterilisation. Neither is a pre-poured agar plate. Choose loop size and packaging for the approved transfer method, not as a substitute for a validated quantitative measurement. Confirm the discard container’s chemical and heat compatibility before use.

Teaching-culture option — selection by qualified staff

The linked culture is a purchasing option, not automatic approval for the activity. Obtain the exact supplied strain details and handling instructions, and match them to the school’s current assessment. Do not infer suitability from the species name alone or substitute a different isolate.

Supporting equipment and protection — catalogue searches